采用空气源热泵供应热水,当全日制热水供应系统与定时热水供应系统采用一套热水供应设备时,就要考虑贮热水箱(罐)贮热水容积计算方法,该文对此进行了探讨分析,提出了一种原创性的计算方法,可供设计人员参考选用。
An air source heat pump is used to supply hot water.When the full time hot water supply system and the timing hot water supply system applies the same set of hot water supply equipment,it is necessary to give thought to the calculation method for the hot water volume of the heat storage tank(can),which is discussed and analyzed,with an original calculation method put forward for reference.
出处
《重庆建筑》
2018年第11期57-59,共3页
Chongqing Architecture
关键词
空气源热泵
贮热水箱(罐)贮热水容积
定时热水供应
全日制热水供应
air source heat pump
hot water volume of a heat storage tank
timing hot water supply system
full time hot water supply system