对制氧机预冷系统空气温度超标的原因进行了分析,并由此实施了防止问题的若干措施,迅速解决了问题。
The causes of excessive air temperature in the precooling system of oxygen generator were analyzed and various measures to prevent the problem were implemented,which has quickly solved the problem.