期刊文献+

Optimizing the value of measuring inferior vena cava diameter in shocked patients 被引量:3

Optimizing the value of measuring inferior vena cava diameter in shocked patients
下载PDF
导出
摘要 Point-of-care ultrasound has been increasingly used in evaluating shocked patients including the measurement of inferior vena cava(IVC) diameter. Operators should standardize their technique in scanning IVC. Relativechanges are more important than absolute numbers. We advise using the longitudinal view(B mode) to evaluate the gross collapsibility, and the M mode to measure the IVC diameter. Combining the collapsibility and diameter size will increase the value of IVC measurement. This approach has been very useful in the resuscitation of shocked patients, monitoring their fluid demands, and predicting recurrence of shock. Pitfalls in measuring IVC diameter include increased intra-thoracic pressure by mechanical ventilation or increased right atrial pressure by pulmonary embolism or heart failure. The IVC diameter is not useful in cases of increased intra-abdominal pressure(abdominal compartment syndrome) or direct pressure on the IVC. The IVC diameter should be combined with focused echocardiography and correlated with the clinical picture as a whole to be useful. Point-of-care ultrasound has been increasingly used in evaluating shocked patients including the measurement of inferior vena cava(IVC) diameter. Operators should standardize their technique in scanning IVC. Relativechanges are more important than absolute numbers. We advise using the longitudinal view(B mode) to evaluate the gross collapsibility, and the M mode to measure the IVC diameter. Combining the collapsibility and diameter size will increase the value of IVC measurement. This approach has been very useful in the resuscitation of shocked patients, monitoring their fluid demands, and predicting recurrence of shock. Pitfalls in measuring IVC diameter include increased intra-thoracic pressure by mechanical ventilation or increased right atrial pressure by pulmonary embolism or heart failure. The IVC diameter is not useful in cases of increased intra-abdominal pressure(abdominal compartment syndrome) or direct pressure on the IVC. The IVC diameter should be combined with focused echocardiography and correlated with the clinical picture as a whole to be useful.
机构地区 Department of Surgery
出处 《World Journal of Critical Care Medicine》 2016年第1期7-11,共5页 世界重症医学杂志
关键词 INFERIOR vena cava DIAMETER POINT-OF-CARE ULTRASOUND Measurement Inferior vena cava diameter Point-of-care ultrasound Measurement
  • 相关文献

同被引文献19

引证文献3

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部