期刊文献+

Postural spinal balance defined by net intersegmental moments: Results of a biomechanical approach and experimental errors measurement

Postural spinal balance defined by net intersegmental moments: Results of a biomechanical approach and experimental errors measurement
下载PDF
导出
摘要 AIM: To describe initial results and experimental error measurement of a protocol analyzing Human posture through sagittal intersegmental moments. METHODS: Postural analysis has been recently improved by development of three-dimensional radiographic imaging systems. However, in various situations such as global sagittal anterior malalignment interpretation of radiographs may not represent the real alignment of the subject. The aim of this study was to present initial results of a 3D biomechanical protocol. This protocol isobtained in a free standing position and characterizes postural balance by measurement of sagittal intersegmental net moments. After elaboration of a specific marker-set, 4 successive recordings were done on two volunteers by three different operators during three sessions in order to evaluate the experimental error measurement. A supplementary acquisition in a "radiographic" posture was also obtained. Once the data acquired, joint center, length, anatomical frame and the center of mass of each body segment was calculated and a mass affected. Sagittal net intersegmental moments were computed in an ascending manner from ground reaction forces at the ankles, knees, hips and the lumbosacral and thoraco-lumbar spinal junctions. Cervicothoracic net intersegmental moment was calculated in a descending manner.RESULTS: Based on average recordings, clinical interpretation of net intersegmental moments(in N.m) showed a dorsal flexion on the ankles(8.6 N.m), a flexion on the knees(7.5 N.m) and an extension on the hips(8.5 N.m). On the spinal junctions, it was flexion moments: 0.34 N.m on the cervico-thoracic; 6.7 N.m on the thoraco-lumbar and 0.65 N.m on the lumbo-sacral. Evaluation of experimental error measurement showed a small inter-trial error(intrinsic variability), with higher inter-session and inter-therapist errors but without important variation between them. For one volunteer the "radiographic" posture was associated to significant changes compared to the free standing position. CONCLUSION: These initial results confirm the technical feasibility of the protocol. The low intrinsic error and the small differences between inter-session and intertherapist errors seem to traduce postural variability over time, more than a failure of the protocol. Characterization of sagittal intersegmental net moments can have clinical applications such as evaluation of an unfused segment after a spinal arthrodesis. AIM: To describe initial results and experimental error measurement of a protocol analyzing Human posture through sagittal intersegmental moments. METHODS: Postural analysis has been recently improved by development of three-dimensional radiographic imaging systems. However, in various situations such as global sagittal anterior malalignment interpretation of radiographs may not represent the real alignment of the subject. The aim of this study was to present initial results of a 3D biomechanical protocol. This protocol isobtained in a free standing position and characterizes postural balance by measurement of sagittal intersegmental net moments. After elaboration of a specific marker-set, 4 successive recordings were done on two volunteers by three different operators during three sessions in order to evaluate the experimental error measurement. A supplementary acquisition in a "radiographic" posture was also obtained. Once the data acquired, joint center, length, anatomical frame and the center of mass of each body segment was calculated and a mass affected. Sagittal net intersegmental moments were computed in an ascending manner from ground reaction forces at the ankles, knees, hips and the lumbosacral and thoraco-lumbar spinal junctions. Cervicothoracic net intersegmental moment was calculated in a descending manner.RESULTS: Based on average recordings, clinical interpretation of net intersegmental moments(in N.m) showed a dorsal flexion on the ankles(8.6 N.m), a flexion on the knees(7.5 N.m) and an extension on the hips(8.5 N.m). On the spinal junctions, it was flexion moments: 0.34 N.m on the cervico-thoracic; 6.7 N.m on the thoraco-lumbar and 0.65 N.m on the lumbo-sacral. Evaluation of experimental error measurement showed a small inter-trial error(intrinsic variability), with higher inter-session and inter-therapist errors but without important variation between them. For one volunteer the "radiographic" posture was associated to significant changes compared to the free standing position. CONCLUSION: These initial results confirm the technical feasibility of the protocol. The low intrinsic error and the small differences between inter-session and intertherapist errors seem to traduce postural variability over time, more than a failure of the protocol. Characterization of sagittal intersegmental net moments can have clinical applications such as evaluation of an unfused segment after a spinal arthrodesis.
出处 《World Journal of Orthopedics》 2015年第11期983-990,共8页 世界骨科杂志(英文版)
基金 Supported by The Association pour le Développement des Recherches biologiques et Médicales and the French Society of Orthopaedics and trauma surgery(Blondel B)
关键词 POSTURE SAGITTAL alignement BIOMECHANICAL evaluation Intersegmental NET MOMENTS Posture Sagittal alignement Biomechanical evaluation Intersegmental net moments
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部