摘要
背景:薄弱的静脉壁是冠状动脉旁路移植术后大隐静脉桥病变的诱发因素之一。目的:探讨人体大隐静脉桥外膜戊二醛交联对血管生物力学特性的影响。方法:收集冠状动脉粥样硬化性心脏病患者冠状动脉旁路移植术后剩余的大隐静脉40段,随机分A、B组,每组20段,将A组中的每段大隐静脉分成2小段,其中一段采用0.3%戊二醛溶液交联5min,另一段不交联(对照);将B组的每段大隐静脉分成2小段,其中一段采用0.3%戊二醛溶液交联10 min,另一段不交联(对照)。采用荧光显微镜及扫描电镜观察交联前后的血管壁微观形态;利用单轴拉伸测试检测交联前后血管的应力-应变关系、杨氏模量及破坏强度。结果与结论:(1)荧光显微镜:与对照血管相比,交联血管的Ⅰ型胶原纤维呈明显压缩改变,密度显著增大,管腔面结构未见明显差异;(2)扫描电镜:对照血管外膜表面胶原纤维呈现典型的波浪状疏松排列,交联血管外膜表面胶原纤维呈现致密的网状排列;(3)单轴拉伸测试:与对照血管比较,交联5,10min血管的应力-应变曲线明显左移,并且在高应变区(延展率为1.3-1.5)杨氏模量显著增加(P <0.05);与交联5 min血管比较,交联10 min血管的应力-应变曲线明显左移,并且在高应变区(延展率为1.3-1.5)杨氏模量显著增加(P <0.05);交联5,10 min血管的破坏强度高于对照血管(P <0.05);(4)结果表明:血管外膜戊二醛交联增加了大隐静脉血管壁强度,降低了其延展性。
BACKGROUND:Poor venous wall is one of the inducing factors causing saphenous vein failure after coronary artery bypass grafting(CABG).OBJECTIVE:To explore the effects of adventitial glutaraldehyde cross-linking on the biomechanical properties of human saphenous vein graft(SVG).METHODS:Forty residual segments of SVG were collected from the patients undergoing CABG.Those segments were randomly divided into group A(n=20)and group B(n=20).Adventitial cross-linking was performed with 0.3%glutaraldehyde solution.Each SVG segment in group A was equally subdivided into two parts:one for adventitial cross-linking 5 minutes and the other as self-control.Each SVG segment in group B was also equally subdivided into two parts:one for adventitial cross-linking 10 minutes and the other as self-control.The ultra-structural changes of the venous wall with or without cross-linking were observed by fluorescence microscope and scanning electron microscope.The SVG segments in two groups underwent the uniaxial stretch test to detect the stress-strain relationship,Young’s elastic modulus and breaking strength of SVG segments receiving different processing.RESULTS AND CONCLUSION:(1)Fluorescence microscope:Compared with the SVGs of self-control,cross-linked SVGs mainly presented with compacted adventitial monomer of collagen and increased density of type I collagen,without obvious ultra-structural changes in the lumen surface.(2)Scanning electron microscope:The adventitial collagen fibers in the self-control segments showed a typical wavy loose arrangement,while the adventitial collagen fibers in the cross-linked segment appeared to have a dense fibrous network.(3)Uniaxial stretch test:Compared with the self-control parts,the stress-stretch ratio curve in the cross-linked parts in the two groups was shifted to the left remarkably,and in the high strain region(stretch ratio 1.3-1.5),the Young’s elastic modulus was also increased significantly(P<0.05).Compared with the SVGs in the cross-linking 5 minutes,the stress-stretch ratio curve in the SVGs in the cross-linking 10 minutes was shifted to the left remarkably,and in the high strain region(stretch ratio 1.3-1.5),the Young’s elastic modulus was also increased significantly(P<0.05).The breaking strength of cross-linked SVGs was higher than that of self-control SVGs in the two groups(P<0.05).To conclude,adventitial glutaraldehyde cross-linking reinforces venous wall and reduces the ductility of human SVG.
作者
方颖
刘长城
顾承雄
于洋
李振峰
许欢明
陈端端
Fang Ying;Liu Changcheng;Gu Chengxiong;Yu Yang;Li Zhenfeng;Xu Huanming;Chen Duanduan(Department of Cardiac Surgery,Beijing Anzhen Hospital,Capital Medical University,Beijing 100029,China;Beijing Institute of Heart Lung and Blood Vessel Diseases,Beijing 100029,China;Department of Biomedical Engineering,School of Life Science,Beijing Institute of Technology,Beijing 100081,China;Key Laboratory of Convergence Medical Engineering System and Healthcare Technology,the Ministry of Industry and Information Technology,Beijing 100081,China)
出处
《中国组织工程研究》
CAS
北大核心
2019年第2期226-231,共6页
Chinese Journal of Tissue Engineering Research
基金
国家自然科学基金(81370436
项目负责人:顾承雄~~