期刊文献+

低电压穿越对给煤机变频器影响的试验与研究 被引量:4

Test and research of the low voltage ride-through influence on the converter of coal feeder
下载PDF
导出
摘要 为了避免电厂由于系统低电压扰动而造成给煤机跳闸,从而触发机组保护动作,针对浙江浙能兰溪发电有限责任公司设备的具体情况,开展了低电压对给煤机变频器影响的试验与研究,提出了一种适合中速磨煤机正压直吹式制粉系统的给煤机变频器低电压穿越的方法。 In order to avoid the power plant tripping due to low voltage disturbance of the power plant which triggers the protection action of the unit,the test of the influence of low voltage on the converter of the coal feeder was carried out according to the specific conditions of the equipment of Zhejiang Energy Lanxi Power Generation Company Limited. It proposed a method of low voltage ride-through for coal feeder frequency converter of directfiring pulverizing system with middle speed mill.
作者 韩峰 余程
出处 《华电技术》 CAS 2018年第11期48-51,79,共5页 HUADIAN TECHNOLOGY
关键词 给煤机 变频器 低电压穿越 coal feeder frequency converter low voltage ride through