摘要
文章对4块预制混凝土夹心墙板的热工性能进行试验研究,通过变化连接件的种类,探索连接件对墙板热工性能的影响。试验结果表明:连接件的热桥效应明显,与无连接件的预制墙板相比,采用纤维连接件的墙板的传热系数提高8%,而采用不同金属连接件的墙板的传热系数分别提高20.9%与14.3%。因此,在实际工程应用中,采用不同连接件时,建议对墙板的相关热工性能参数进行相应折减。
In this paper,the thermal performance of four prefabricated concrete sandwich panels were tested,The influence of the shear connectors on the thermal performance of the whole wall panel were explored by transforming the types of connectors.Test results showed that the thermal bridge effect caused by shear connectors was obviously.Compared with the prefabricated sandwich panel without connectors,the heat transfer coefficient of the wall panel with fiber connectors was increased by8%,while the wall panels with different metal connectors were increased by20.9%and14.3%,respectively.Therefore,the relevant thermal performance parameters of the sandwich panels should be made any amplification factor when they used in actual applications.
作者
魏燕丽
朱文祥
许锦峰
吴志敏
张海遐
WEI Yan-li;ZHU Wen-xiang;XU Jin-feng;WU Zhi-min;ZHANG Hai-xia(Jiangsu Research Institute of Building Science Co.,Ltd,Jiangsu Province Key Laboratory of Research of Green Building and Structural Safety,Nanjing Jiangsu 210008 China)
出处
《江苏建筑》
2018年第B11期59-61,共3页
Jiangsu Construction
基金
国家十三五重点研发项目子课题(2016YFC0701402)
江苏省建科院公司合作创新引导资金项目:保温防水装饰一体化预制大型墙板关键技术与应用研究
关键词
预制夹心墙板
热工性能
连接件
precast sandwich wall panel
thermal performance
connector