期刊文献+

嵌砌式保温砌筑一体化系统节能计算 被引量:1

Energy Saving Calculation of Embedded Thermal Insulation Masonry Integration System
下载PDF
导出
摘要 严寒地区建筑的能源消耗主要来自冬季采暖,合理的围护结构节能设计可以在确保建筑内部温度适宜前提下,最大限度地降低建筑的能源消耗。分析总结几种常见外墙保温体系应用于严寒地区的优缺点,通过计算验证传统单一材料自保温体系与嵌砌式保温砌筑一体化系统在严寒地区的适用性。结果表明传统单一材料自保温体系的保温性能在适宜的外墙厚度下无法满足严寒地区的节能设计要求,而嵌砌式泡沫混凝土保温砌筑一体化系统在适宜的外墙厚度下则可以满足节能设计要求。因此,嵌砌式泡沫混凝土保温砌筑一体化系统可以在严寒地区推广使用。 Heating in winter is the major energy consumption of buildings in cold region.It is possible that the interior temperature of the building is suitable and the energy consumption of buildings can be minimized when reasonable energy saving design of envelope is adopted.The applicability of traditional single material self-insulation system and embedded thermal insulation masonry in cold region is compared by energy saving calculation.The results show that thermal insulation performance of traditional single material self-insulation system with suitable external wall thickness cannot meet the energy saving design requirements in cold region,while embedded foam concrete thermal insulation masonry integration system with suitable external wall thickness can meet the energy saving design requirements.Therefore,embedded foam concrete thermal insulation masonry integration system can be utilized in cold region.
作者 巩玉发 王泓懿 GONG Yu-fa;WANG Hong-yi(College of Architecture and Transportation,Liaoning Technical University,Fuxin 123000,Liaoning,China)
出处 《建筑节能》 CAS 2018年第12期58-61,共4页 BUILDING ENERGY EFFICIENCY
关键词 严寒地区 外墙自保温体系 节能设计 传热系数 嵌砌式保温砌筑 cold region exterior wall self-insulation system energy saving design heat transfer coefficient embedded thermal insulation masonry integration system
  • 相关文献

参考文献3

二级参考文献25

共引文献43

同被引文献15

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部