根据常规pH分析仪测量纯水的干扰因素,分析了导致我国现阶段发电厂测量pH值困难的原因,介绍了计算型pH分析仪原理、结构、测点及应用,发现计算型pH分析仪可以完全适应我国目前发电厂化学监督的要求。
According to the interference factors of measuring pure water by conventional pH analyzer,this paper analyses the reasons that cause the difficulty of measuring pH value in power plants at present in our country,introduces the principle,structure,measuring point and application of the calculating pH analyzer,and finds that the calculating pH analyzer can fully meet the requirements of chemical supervision in power plants in our country.
作者
葛福进
王勇
Ge Fujin;Wang Yong(Nanjing Alex Hua Tian technology development Limited by Share Ltd,Nanjing 210019,china)
出处
《云南化工》
CAS
2018年第10期234-235,共2页
Yunnan Chemical Technology
关键词
计算型pH分析仪
发电厂
低电导率水
化学监督
Computational PH analyzer
Power plant
Low conductivity water
Chemical supervision