摘要
介绍了龙口水电站WDST-100型调速器的结构和特点,针对该型调速器抽动、自动水头功能未投入、调速器在线机频繁切换以及小网标志频繁动作等典型电气故障,分析故障原因,提出故障处理方法,为水电站调速器维护工作提供参考。
The architecture and characteristics of Longkou hydropower station WDST-100governor are introduced firstly.Typical electrical failure,for example,spasm of the main distribution valve,automatic head signal function failure to be invested,frequent action of on-line machine and isolated network operation mark are described in detail from fault phenomenon,fault cause analysis and fault treatment.The ideas and methods of solving the problems are expected to provide reference ideas for the governor maintainers of hydropower stations.
作者
赵远新
赵喜波
宋洋洋
张春龙
ZHAO Yuanxin;ZHAO Xibo;SONG Yangyang;ZHANG Chunlong(Y.R.Wanjiazhai Multiple-Purpose Dam Project Co.,Ltd.,Taiyuan030002,China)
出处
《内蒙古电力技术》
2018年第6期66-70,共5页
Inner Mongolia Electric Power
关键词
水电站
调速器
抽动
自动水头
频繁动作
电气故障
hydropower station
governor
spasm
automatic head signal
frequent action
electrical faults