摘要 材质为316L不锈钢的半成品柴油输送管道在水平段底部出现快速腐蚀,9个月出现5次泄露。通过宏观分析、化学成分检测、力学性能测试、金相分析、腐蚀产物物相分析、腐蚀介质有害相分析、腐蚀产物分析等方法,对管道失效原因进行分析。结果表明:不锈钢管线腐蚀属于氧腐蚀及点蚀;氧化铁等腐蚀产物或杂质随介质在管线底部流动,对管线底部形成线状冲刷磨损,破坏了钝化膜的保护作用,造成管线底部率先腐蚀;腐蚀环境中Cl^-极易破坏不锈钢表面的钝化膜,形成坑蚀,成为孔蚀延伸的活性中心。 Rapid corrosion occurred to a semi-finished diesel pipeline made of 316L stainless steel at the bottom of the horizontal section,for 5 times within 9 months.The causes for the pipeline failure were analyzed by macroscopic analysis,chemical composition analysis,mechanical properties testing,metallographic analysis,corrosion product phase analysis,harmful phase analysis of corrosive media,and corrosion product analysis.The results show that the corrosion of the stainless-steel pipeline is oxygen corrosion and pitting corrosion.Corrosion products or impurities such as iron oxides flowed along the bottom of the pipeline with the media,leading to linear erosion wear on the bottom of the pipeline and damaging the protective effect of passivating film.As a result,the bottom of the pipeline was first corroded.Chlorine ions inthe corrosion environment can easily destroy the passivating film on the surface of stainless steel,forming pitting corrosion and becoming the active center of hole corrosion extension.
作者 刘铭奇 董逢寅 董羲武 LIU Ming-qi;DONG Feng-yin;DONG Xi-wu(National Quality Supervision and Inspection Center of Petroleum Equipment and Products,Shandong Dongying 257000,China)
出处 《失效分析与预防》 2018年第6期373-377,共5页 Failure Analysis and Prevention
关键词 化工厂 316L 水平段底部 Cl^- 氧腐蚀 chemical plant 316L bottom of horizontal section Cl^- oxygen corrosion
  • 相关文献

参考文献9

二级参考文献66

共引文献307

同被引文献21

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部