摘要
三门AP1000项目采用OVATION系统实现电厂非安全相关的控制、监测和保护等功能。本文介绍了三门AP1000OVAITON系统采用的冗余设计应用,如电源冗余、网络冗余、控制器冗余以及部分I/O卡冗余等,提高了系统可靠性。
The Ovation system is used for non-safety related control,monitor and protect function for Sanmen AP1000Project.This paper introduces the Redundancy Design in Sanmen AP1000Ovation System,such as Power redundant,Network redundant,Controller redundant and I/O redundant and so on,which improves the reliability of Ovation system.
作者
刘标
Liu Biao(Sanmen Nuclear Power Company, Zhejiang, Taizhou, 317112, China)
出处
《仪器仪表用户》
2019年第2期78-80,109,共4页
Instrumentation