期刊文献+

地回线对容性耦合钳快速瞬态脉冲注入的影响

Effects of ground return wires on fast transient pulses injection by capacitive coupling clamp
下载PDF
导出
摘要 介绍了容性耦合快速瞬态脉冲抗扰度试验方法,分析了线束间的不同耦合路径,并通过实验法验证了地回线对试验结果的影响。最后,为试验的实施提出了理论指导。 The fast-transient pulses immunity test by capacitive coupling are introduced.Different coupling paths in wiring harness are discussed.The effects of ground return wires on test results are experimentally verified.Meanwhile,technical suggestions were purposed for test implementation.
作者 周慧华 邹喜萍 Zhou Huihua;Zou Xiping(Tongji University;Shanghai Jiao Tong University)
出处 《上海计量测试》 2018年第6期14-15,18,共3页 Shanghai Measurement and Testing
关键词 电磁兼容 容性耦合钳 地回线 快速瞬态 ISO 7637-3 electromagnetic compatibility(EMC) capacitive coupling clamp ground return wires fast transient ISO 7637-3
  • 相关文献

参考文献1

二级参考文献5

  • 1[美]ClaytonRPaul.电磁兼容导论[M].闻映红,译.北京:人民邮电出版社,2007:367-456.
  • 2Wolfgang J R Hoefer.The Transmission-Line Matrix Method-Theory and Applications[J].IEEE Transactions on Microwave Theory and Techniques,1985,33(10):882-893.
  • 3Clayton R Paul.Solution of the Transmission-Line Equations Under the Weak-Coupling Assumption[J].Electromagnetic Compatibility,2002,44(3):413-423.
  • 4International Electrotechnical Commission.CISPRI6-2-1:2010 [S].Geneva,2010.
  • 5高印寒,王瑞宝,李碧若,谢军,杨开宇.汽车线束电感性串扰动态变化的预测[J].光学精密工程,2011,19(5):1088-1094. 被引量:10