摘要
目的:探讨TP-ELISA作为初筛方法的梅毒逆向筛查程序的可行性分析。方法:选择2016年1月至2017年6月在大连大学附属中山医院各门诊及病房就诊的梅毒筛查者,并收集其标本15378份,采用梅毒螺旋体抗体酶联免疫吸附试验(TP-ELISA)、梅毒螺旋体明胶颗粒凝集试验(TPPA)与甲苯胺红不加热血清学试验(TRUST)筛选分析。以TPPA为标准,比较各种方法的特异性、灵敏度以及总符合率,统计TP-ELISA的S/CO值与TPPA阳性结果的相关性。结果:TPPA筛查阳性率为3. 57%,TP-ELISA筛查阳性率为3. 83%,TRUST筛查阳性率为2. 38%。TP-ELISA的灵敏度(98. 9%)明显优于TRUST(64. 3%),差异具有统计学意义(P <0. 01)。TP-ELISA与TRUST特异性与符合率差异无统计学意义(P> 0. 05)。梅毒筛查时,TP-ELISA与TPPA在梅毒筛查时有较好的一致性(K=0. 945),TRUST与TPPA一致性不明显(K=0. 639)。根据梅毒抗体检测的特点以及实验室TP-ELISA的检测方法,当≤1. 0时,S/CO为阳性,> 1. 0时S/CO为阳性。TP-ELISA检测结果的假阳性样本率为75. 00%(54/72),其主要是发生在S/CO值1. 0~2. 99之间。随着TP-ELISA的S/CO的数值增高,TPPA的符合率也依次增加,S/CO> 5. 0时,TPPA的阳性率为100%。TRUST的检测阳性样本有13例,患者主要有妇产科正常妊娠8例,口腔科牙周炎3例,心内、呼吸2例。TP-ELISA假阴性6例,其中分布为泌尿科患者3例,骨科患者1例,妇产科患者2例,其被疑为梅毒早期。TP-ELISA假阳性患者72例。结论:TP-ELISA的灵敏度和特异性显著优于TRUST,有利于梅毒筛查效果,值得临床上大样本筛查。
Objective:To explore the feasibility of TP-ELISA as a screening method for syphilis reverse screening program.Methods:A total of 15378 specimens were collected from January 2001 to June 2017 in the outpatient and ward offices of our hospital.Screening was conducted by trypsin antibody-linked immunosorbent assay(TP-ELISA),treponema pallidum particle agglutination assay(TPPA) and toluidine red unheated serological test(TRUST).The specificity,sensitivity and total coincidence rate of each method were compared with TPPA,and the correlation between TP/ELISA S/CO and TPPA positive results was statistically analyzed.Results:The positive screening rate of TPPA,TP-ELISA and TRUST was 3.57%,3.83%and 2.38%respectively.The sensitivity of TP-ELISA(98.9%)was significantly better than that of TRUST(64.3%),with statistically significant difference(P<0.01).The differences in specificity and compliance rates between TP-ELISA and TRUST were not statistically significant(P>0.05).In terms of syphilis screening,TP-ELISA and TPPA had a good consistency(K=0.945),while the consistency between TRUST and TPPA was not significant(K=0.639).According to the characteristics of the antibody detection of syphilis and the test method of the laboratory TP-ELISA,S/CO was positive when no less than 1.0,and was negative when>1.0.The TP-ELISA test results had a false positive sample rate of 75.00%(54/72),which was mainly between the S/CO value of 1.0~2.99.With the increase in S/CO of TP-ELISA,the compliance rate of TPPA also increased and TPPA reached 100%with the ratio of S/CO>5.0.Among the 13 test positive samples of TRUST,there were 8 cases of normal pregnancy,3 cases of oral cavity and 2 cases in the heart and breathing.Among the 6 cases of TP-ELISA false negative,there were 3 cases in urology department,a case in orthopedic department and 2 cases in gynecologic and obstetric department,all were suspected of early syphilis.There were 72 cases of TPELISA false positive.Conclusions:The sensitivity and specificity of TP-ELISA is significantly better than that of TRUST,which is beneficial to the screening of syphilis and worthy of large sample screening in clinic.
作者
姜黎黎
张玉萍
尚爱民
JIANG Lili;ZHANG Yuping;SHANG Aimin(Department of Dermatology,Zhongshan Hospital Affiliated to Dalian University,Dalian 116001,Liaoning,China)
出处
《中国性科学》
2018年第11期112-114,共3页
Chinese Journal of Human Sexuality
基金
辽宁省科技厅重点攻关项目(102102345485)
关键词
梅毒
梅毒螺旋体抗体酶联免疫吸附试验
梅毒螺旋体明胶颗粒凝集试验
甲苯胺红不加热血清学试验
逆向筛查
Syphilis
Treponema pallidum-enzyme linked immunosorbent assay(TP-ELISA)
Treponema pallidum particle agglutination assay(TPPA)
Toluidine red unheated serological test(TRUST)