期刊文献+

加氢装置换热器结垢腐蚀原因及措施 被引量:1

Causes and Countermeasures for Scaling and Corrosion of Heat Exchanger in a Hydrogenation Unit
下载PDF
导出
摘要 针对加氢装置换热器结垢腐蚀问题进行了研究,利用XRF、元素分析仪等分析黑色物质的组成,并从形成机理、物料来源等方面分析原因,提出了有效解决加氢装置换热器结垢腐蚀问题的措施。 The scaling and corrosion problems of heat exchanger in a hydrogenation unit at Sinopec Tianjin Branch were studied.The composition of black substance was analyzed by XRF and elemental analyzer.The causes were investigated from the aspects of formation mechanism and material sources,and countermeasures that could effectively solve the scaling and corrosion problems were put forward.
作者 崔蕊 侯志忠 刘嫘 于焕良 Cui Rui;Hou Zhizhong;Liu Lei;Yu Huanliang(SINOPEC Tianjin Branch, Tianjin, 300270)
出处 《安全、健康和环境》 2018年第12期37-39,共3页 Safety Health & Environment
关键词 加氢装置 换热器 结垢腐蚀 原因 措施 hydrogenation unit heat exchanger scaling and corrosion cause countermeasure
  • 相关文献

参考文献4

二级参考文献21

  • 1张贵才,马涛,葛际江,齐宁.聚氧乙烯烷基苯酚醚磷酸酯用作缓蚀剂的研究[J].石油学报(石油加工),2005,21(2):45-50. 被引量:22
  • 2马欣.金属在含氯离子水介质中的腐蚀行为[J].石油化工腐蚀与防护,2005,22(5):5-9. 被引量:37
  • 3李淑英.循环冷却水系统中立式蒸发器腐蚀原因分析[J].材料科学与工艺,2007,15(1):31-34. 被引量:4
  • 4[1]Gullett B K, Jozewiez W , Stefanski L A. [ J ] . Ind Eng Chem Res ,1992,31:2437.
  • 5[2]Wang W Y.[J].Fuel,1996,75(2):202.
  • 6[3]陈克勋.铁系常温脱氯剂的性能及反应动力学研究[D].武汉:湖北化学研究所,2001.
  • 7[4]Iwaji I,Satori U,et al. [J]. Bull Chem Soc Jpn,1995,29(8) :860~ 864.
  • 8[5]James J C, et al. Chemical Industries/26, Chemical Reaction and Reactor Engineering[ M]. New York: Marcel Dekker, 1987.298~300.
  • 9[6]Krishnan G N,et al,DOE/MC/30005 -96/C0504.
  • 10Cabrera-Sierra R,Miranda-Hernandez M,Sosa E,et al.Electrochemieal characterization of the different surface states formed in the corrosion of carbon steel in alkaline SOUr medium[J7.Corros Sci,2001,43(12):2305-2324.

共引文献31

同被引文献3

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;