常压塔顶部挥发线露点腐蚀与多相流模拟 被引量:3

Study on Dew Point Corrosion with Multiphase Flow Simulation at The Overhead Vapor Line of the Atmospheric Tower
下载PDF
导出
摘要 运用CFD仿真软件Fluent,参考国内某炼厂常压塔挥发线管道结构和运行工况,对注水后管道内的多相多组分状态进行了模拟,编写了相应的传热传质模型,对其中的腐蚀性介质参数进行了计算分析,结果表明:在注入中性水后,挥发线管道内气相腐蚀性介质HCl和H_2S在水相中快速溶解,导致水相pH值呈酸性,注水点下游附近出现了液相跌落区,此处的pH值最低。对不同的注水流量和液滴粒径的注水工况进行模拟后,发现注水参数对跌落区的位置、最低pH值产生了影响,其中液滴粒径的影响更加显著。据此,预测了不同注水工艺对塔顶露点腐蚀状态的影响,以期指导腐蚀监测和工艺防腐。 In order to study the dew point corrosion of the overhead pipeline,a CFD simulation software,Fluent,was used to simulate the multiphase and multi-component state in the pipeline after water injection based on the actual pipeline structure and operation conditions of a domestic refinery.The models of heat and mass transform were compiled and the parameters of corrosivesin the pipeline were calculated and analyzed.The results showed that after fresh neutral water was injected,the corrosivessuch as hydrochloric and hydrogen sulfide gas rapidly dissolved into the water phase and turned the solution to acidic in the pipeline.The initial condensation zone was locatednearthe downstream from the injection point,where the pH value was the lowest.It was also found that theposition of the initial condensing area lowest pH value changed with water flow rate and droplet size,with a bigger impact from the latter.Based on this,the influence of different technologies of water injection on the dew point corrosion state of the overhead system wasstudied,which couldguide thedesign of effective anti-corrosion methods.
作者 陈冰川 张龙 韩磊 张艳玲 屈定荣 刘小辉 Chen Bingchuan;Zhang Long;Han Lei;Zhang Yanling;Qu Dingrong;Liu Xiaohui(Shanghai Jiding Information Technology Co., Ltd., Shanghai, 200433;SINOPEC Qingdao Research Institute of Safety Engineering, Shandong, Qingdao, 266071)
出处 《安全、健康和环境》 2018年第12期49-54,共6页 Safety Health & Environment
关键词 常压塔 露点腐蚀 多相流 计算流体力学 atmospheric tower dew point corrosion multiphaseflow computational fluid dynamics
  • 相关文献

参考文献4

二级参考文献13

  • 1李鹤林.失效分析的任务、方法及其展望[J].理化检验(物理分册),2005,41(1):1-6. 被引量:36
  • 2钟群鹏.失效分析与安全[J].理化检验(物理分册),2005,41(5):217-221. 被引量:5
  • 3刘香兰,王凤英,贺兵.常减压蒸馏装置的腐蚀与控制[J].全面腐蚀控制,2007,21(2):30-33. 被引量:1
  • 4U.S.Chemical Safety Board.Completed Investigations[EB/OL].[2015-03-10].http://www.csb.gov/investigations/completed-investigations/?Type=2.htm.
  • 5畑村創造工学研究所.Failure Knowledge Database[EB/OL].[2015-03-10].http://www.sozogaku.com/fkd/en/index.html.htm.
  • 6Bureau for Analysis of Industrial Risks and Pollutions(BARPI).Chemistry and Petroleum[EB/OL].[2015-03-10].http://www.aria.developpement-durable.gouv.fr/category/accident-reports/chemistry-and-petroleum/?lang=en.htm.
  • 7European Commission Joint Research Center.EMARSMajor Accident Reporting System[EB/OL].(2012-06-09)[2015-03-10].https://emars.jrc.ec.europa.eu/?id=4.htm.
  • 8API RP 571-2011 Damage Mechanisms Affecting Fixed Equipment in the Refining Industry[S].
  • 9Chosnek,J.Managing Management of Change[J].Process Safety Progress,2010,29(4):384-386.
  • 10丁荣生.常减压塔顶H_2S协同腐蚀及其对策[J].石油化工腐蚀与防护,2000,17(3):28-29. 被引量:11