PET采血管的偏心会使采血管内的负压真空加速泄露,导致采血量不足,同时采血管的偏心还会影响血液的离心实验结果。文章通过对原材料、模具材料、冷却系统、模具装配四个方面分析,找出了影响偏心的原因及改进方法,从根本上解决采血管偏心的问题。
The eccentricity of PET blood collection tubes will accelerate the leakage of negative pressure vacuum in the blood collection tubes,which will lead to insufficient blood collection.At the same time,the eccentricity of the blood collection tubes will affect the results of blood centrifugation experiment.Through the analysis of raw materials,mold materials,cooling system and mold assembly,this paper finds out the reasons of affecting eccentricity and improvement methods,and fundamentally solves the problem of eccentricity of blood collection tubes.
作者
唐娟
刘宗义
张义海
Tang Juan;Liu Zongyi;Zhang Yihai(Sichuan Yibin Push Mold Co. LTD.,Yibin 644000,Sichuan,China)
出处
《橡塑技术与装备》
CAS
2019年第2期31-35,共5页
China Rubber/Plastics Technology and Equipment
关键词
PET采血管
偏心
材料
冷却
PET blood collection tube
eccentricity
material
cooling