采煤机用隔爆水冷三相电动机的散热优化设计 被引量:1

Optimum Design of Heat Dissipation of Flameproof Water-cooled Three-phase Motor for Shearer
下载PDF
导出
摘要 针对采煤机常采用JOY 30EB500J型电机散热性能不足时常导致电机烧毁的问题,对电动机发热的原理进行了分析,从电磁设计、机械结构设计和绝缘设计三方面进行了优化设计。通过实测电动机在连续开机8 h后,电动机中心转子的温度由优化前的95.4℃降低到优化后的64.6℃。说明改进设计符合生产使用中散热的要求。 As to the motor burnout due to the insufficient heat dissipation performance of JOY 30 EB500 J motor in shearers, the principle of motor heating is analyzed, and the optimization design is carried out from electromagnetic design, mechanical structure design and insulation design. After 8 hours of continuous start-up, the temperature of the motor central rotor is reduced from 95.4℃ to 64.6 ℃ after optimization. It shows that the improved design meets the requirements of heat dissipation in production and use.
作者 段小燕 Duan Xiaoyan(Coal Industry Bureau of Liulin County,Lvliang Shanxi 033300)
出处 《机械管理开发》 2018年第12期13-14,24,共3页 Mechanical Management and Development
关键词 JOY30EB500J型电机 电磁设计 机械结构设计 绝缘设计 JOY 30EB500J motor electromagnetic design mechanical structure design insulation design