摘要
受安装空间、高温环境和复杂介质等限制,压力测量系统中往往需要引压管腔来传递压力,管腔成为限制系统频响的重要因素。本文首先回顾了管腔动态特性的理论研究进展,简述了国内外围绕管腔动态特性影响因素的研究成果。其次,介绍了现有的引压管腔主要校准方法,并分析了不同校准方法自身的特点和使用条件。最后,指出了现有校准方法在实际使用中的不足,并对进一步的研究做出展望。
A pipeline or cavity always exists before the pressure transducer when measuring pressure because of the limitation of installation space,high temperature or complex media. The dynamic characteristics of pressure measurement systems are often determined by the pipelines. The progress of the theoretical research in the pipeline dynamic characteristic is first reviewed,and the research results of the factors that are affecting the dynamic characteristic are presented. Then the main calibration methods of pipeline are introduced,and their characteristics and using conditions are analyzed. Finally, the shortcmings of the existing calibration methods in practical use are pointed out, and the further studies needed in the future are discussed.
作者
石玉松
杨军
李博
SHI Yusong;YANG Jun;LI Bo(Changcheng Institute of Metrology & Measurement,Beijing 100095,China)
出处
《计测技术》
2018年第6期2-5,共4页
Metrology & Measurement Technology
基金
国家“十三五”技术基础项目(JSJL2015205B015)
关键词
动态压力
测量
引压管腔
动态特性
校准
dynamic pressure
measurement
pressure pipeline
frequency response
calibration