摘要 介绍国家建筑标准设计图集18DX009《数据中心工程设计与安装》供配电章节以10 kV发电机组作为备用电源的系统, 10 kV发电机组N或N+X、 2N几种配置,与GB 50174-2017 《数据中心设计规范》规定的各级数据中心的适用关系,与《Tier Standard:Topology》规定的各级数据中心的适用关系,以利于读者合理选择与使用。 This paper focuses on introducing the system with a 10 kV generator unit as its backup power for power supply and distribution in the national building standards design atlas 18DX009 Engineering Design and Installation of Data Centers,N,N+X or 2N configurations of 10 kV generator unit,the applicable relationship with the data centers specified in the Code for Design of Data Centers(GB 50174-2017),and the applicable relationship with the data centers specified in the Tier Standard:Topology,in order to assist readers in proper selection and use.
作者 晁怀颇 CHAO Huaipo(S.Y.Technology,Engineering&Construction Co.,Ltd.,Beijing 100142,China)
出处 《建筑电气》 2019年第1期9-13,共5页 Building Electricity
关键词 数据中心 供配电 备用电源 10 kV发电机 配置 并机方式 等级 适用关系 data center power supply and distribution backup power 10 kV generator configuration parallel operation mode class applicable relationship