期刊文献+

Geant4中不同物理列表对硼中子俘获治疗剂量分布的影响 被引量:2

Effects of different Geant4 physics lists on boron neutron capture therapy dose calculation
下载PDF
导出
摘要 Geant4是基于C++编写的开源蒙特卡洛模拟软件,提供多种包含中子与物质相互作用的物理列表。本研究采用Geant4提供的几种物理列表,对沿中子束方向的总吸收剂量、硼剂量和非硼剂量深度分布进行计算,并与FLUKA进行比较,模拟中子能量从0.025 3 eV到10 MeV。对于整个模拟中子能段,结果显示添加S(α,β)热模型的高精度中子物理列表(Geant4_HP_T)在总吸收剂量、硼剂量和非硼剂量深度分布上均与FLUKA符合很好,初步验证了Genat4能应用于硼中子俘获治疗(BNCT)相关研究。对于低能中子(<1 MeV),S(α,β)热模型对BNCT剂量深度分布的影响较大,QBBC和QGSP_BERT不适用于BNCT剂量分布计算。 Geant4 is an open source Monte Carlo simulation toolkit written in C++,and it provides a variety of physical lists including neutron interactions with matter.Herein several physical lists given by Geant4 are used to calculate the depth distributions of total absorption dose,boron dose and non-Boron dose along the direction of the neutron beam,and the obtained results were compared with FLUKA.The simulation neutron energy is from 0.025 3 eV to 10 MeV.In the studied energy range,the results show that the high-precision neutron physics list(Geant4_HP_T)with S(α,β)thermal model agrees well with FLUKA in the depth distributions of total absorbed dose,boron dose and non-boron dose,which preliminarily verifies that Geant4 can be used in the researches on boron neutron capture therapy(BNCT).For low energy neutrons(<1 MeV),the S(α,β)thermal model has remarkable effects on the depth distribution of BNCT dose,and both QBBC and QGSP_BERT aren't suitable for the calculation of BNCT dose distributions.
作者 陈昭 雷琴 杨鹏 文玉梅 何冬林 吴章文 勾成俊 CHEN Zhao;LEI Qin;YANG Peng;WEN Yumei;HE Donglin;WU Zhangwen;GOU Chengjun(Key Laboratory for Radiation Physics and Technology of Ministry of Education/Institute of Nuclear Science and Technology,SichuanUniversity,Chengdu 610064,China)
出处 《中国医学物理学杂志》 CSCD 2019年第1期1-5,共5页 Chinese Journal of Medical Physics
基金 国家重点研发计划(2016YFC0105103)
关键词 硼中子俘获治疗 硼剂量 非硼剂量 剂量深度分布 GEANT4 FLUKA boron neutron capture therapy boron dose non-boron dose dose depth distribution Geant4 FLUKA
  • 相关文献

参考文献1

二级参考文献12

  • 1IAEA. Current Status of Neutron Capture Therapy. IAEA - TEC- DOC - 1223 [ R]. Vienna, 2001.
  • 2http ://neurosurgery. mgh. harvard. edu/brookhav. htm.
  • 3http ://www. bnct. bidmc. harvard. edu/.
  • 4Tetsuo Matsumoto, Otohiko Aizawa. Dose measuring system for bo- ron neutron capture therapy[ J]. Nuclear Instruments and methods in Physics Research, 1988 ( A 271):662-670.
  • 5Aschan C, Toivonen M. TL detectors in BNCT dosimetry. IAEA - TECDOC - 1223 [ R ]. Vienna : 2001,165 - 174.
  • 6Bilski P, Budzanowski M, Ochab E, et al. Dosimetry of BNCT beams with novel thermoluminescent detectors [ J ]. Radiation Pro- tection Dosimetry, 2004, 110 ( 1 - 4) :623 - 626.
  • 7Pawel Bilski, Natalia Golnik, Pawel Olko, et al. Improved dosime- try for BNCT by activation foils, modified thermoluminescent detec- tors and recombination chambers [ J ]. NUKLEONIKA, 2004, 49 (2) :51 -56.
  • 8Moil Chizuo, Osada Taichi, Yanagida Katsuo, et al. Simple and Quick Measurement of Neutron Flux Distribution by Using an Opti- cal Fiber with Scintillator [ J ]. Journal of Nuclear Science and Technology, 1994, 31 (3) : 248 -249.
  • 9Mori C, Uritani A, Miyahara H, et al. Measurement of neutron and γ- ray intensity distributions with an optical fiber - scintillator de- tector[ J]. Nuclear Instrument and Methods in Physics Research A, 1999, 422 : 129 - 132.
  • 10Ito Y, Katano G, Harano H, et al. Development of a tiny neutron probe with an optical fiber for BNCT[J]. Radiation Protection Do-simetry, 2004, 110(1 -4) : 619 -622.

共引文献6

同被引文献6

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部