摘要 四肢骨折为常见骨折类型,以往多采取切开复位内固定术治疗,患者多可获得较好恢复,但术后易出现相关并发症。据报道[1],四肢骨折采取切开复位内固定术的并发症发生率为5%~10%,不利于患者骨折愈合及患肢功能恢复。近年来,骨折内固定原则发生改变,微创经皮钢板接骨术应运而生[2-3]。锁定钢板设计独特,钢板、螺钉之间成角稳定,其与微创经皮钢板接骨术联合是治疗四肢骨折的理想选择[4]。本研究以120例四肢骨折患者为例,对微创经皮钢板接骨术联合锁定钢板的治疗效果进行观察。
作者 李建伟
机构地区 解放军第
出处 《创伤外科杂志》 2019年第1期70-71,共2页 Journal of Traumatic Surgery
  • 相关文献

参考文献7

二级参考文献53

  • 1李文生,陈永峰.MIPPO技术与开放性手术在治疗胫骨骨折的疗效比较[J].医学信息(医学与计算机应用),2014,0(18):143-144. 被引量:1
  • 2杨五一,马骥,胡建斌,杨先甲,袁瑞利,刘德志.弹性髓内钉治疗儿童长骨骨折43例[J].现代养生,2013,0(16):64-64. 被引量:1
  • 3中华人民共和国卫生部.医院感染诊断标准(试行)[S].[S].中华人民共和国卫生部,2001.2.
  • 4中华人民共和国卫生部.外科手术部位感染预防与控制技术指南[S].北京:中华人民共和国卫生部,2010.
  • 5Zou J, Shi ZM, Zhang W, et al. Open reduction and internal fixation better than percutaneous plate osteosynthesis in dis- tal tibial fractures[J]. J Invest Surg, 2012,25 (5) : 326-329.
  • 6Livani B, Belangero WD, Castro-de-Medeiros R, et al. Frac- tures of the distal third of the humerus with palsy of the ra- dial nerve: management using minimally-invasive percutane- ous plate osteosynthesisEJ]. J Bone Joint Surg Br, 2006,88 (12) :1625-1628.
  • 7Ruchholtz S, EI-Zayat B, Kreslo D, et al. Less invasive po- lyaxial locking plate fixation in periprosthetic and peri-im- plant fractures of the femur-a prospective study of 41 patients I-J]. Injury,2013,44(2) :239-248.
  • 8Grawe B, Le T, Williamson s, et al. Fracture fixation with two locking screws versus three non-locking screws: A biomechani- cal comparison in a normal and an osteoporotic bone model [J]. Bone Joint Res, 2012, 1(6): 118-124.
  • 9Paul A Verbeek, Inge van den Akker-Scheek, Klaus W Wendt, et al. Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part frac- tures of the proximal humerus in the elderly., design of a ran-domized controlled trial[J]. BMC Musculoskelet Disord, 2012, 13: 16.
  • 10PERREN SM. Trends in internal fixation potential, limits and requirements[J]. Injury, 1999, 30(1): B2-4.