期刊文献+

高炉热风管道系统膨胀缝设置

Layout of Expansion Joints in Hot-blast Air Pipe System for Blast Furnace
下载PDF
导出
摘要 针对传统高炉热风管道系统膨胀缝留设过大、不合理的问题,分析了热风管道工作层砖和轻质隔热砖的膨胀和收缩性质,提出了合理的热风管道膨胀缝设置方法,在生产实践中应用效果良好,对热风管道砌筑具有指导意义。 In allusion to the problem that the expansion joints reserved in the traditional hot-blast air pipe system for BF were too wide and unreasonable,the expansion character and shrinkage property of the bricks in working lining and light insulation bricks in hot-blast air pipe system were analyzed.And then the reasonable method of designing the expansion joints for the hot-blast air pipe system was proposed.It was demonstrated in production practice that the new designed expansion joints achieved good results,which had the guiding significance in installing the hot-blast air pipe.
作者 李东生 田立明 佟敏英 李晓春 赵德胜 Li Dongsheng;Tian Liming;Tong Minying;Li Xiaochun;Zhao Desheng(General Ironmaking Plant of Angang Steel Co.,Ltd.,Anshan 114021,Liaoning,China)
出处 《鞍钢技术》 CAS 2019年第1期25-27,共3页 Angang Technology
关键词 高炉 热风管道 膨胀缝 热膨胀性 重烧线变化 耐火泥浆 blast furnace hot-blast air pipe expansion joint thermal expansion property linear change on reheating refractory slurry