摘要
植入心脏电子装置的患者既往被归为磁共振成像检查的绝对禁忌证,严重影响了此类患者疾病的诊断和预后。应运而生的磁共振成像兼容心脏电子植入装置使其在磁共振成像检查的安全性方面有了很大进展。当前大量研究证明传统心脏电子植入装置在特定的编程和监测下行磁共振成像检查同样是安全的,现重点介绍不同类型心脏电子装置植入患者行磁共振成像检查的最新进展。
Cardiac implanted electronic devices(CIED) recipients have historically been regarded as an absolute contraindication for performing magnetic resonance imaging(MRI),and it seriously affected the diagnosis and prognosis of these patients.The application of MRI-conditional CIED make the safety of MRI advanced greatly.However,the current aggregated studies robustly demonstrated that conventional CIED is as safe as MRI-conditional CIED in the specific programming and monitoring of MRI.This article focus on the latest advances of the MRI safety in different classifications of CIED recipients.
作者
郭晨
吕永会
李敏
张明卜
王志禄
GUO Chen;L Yonghui;LI Min;ZHANG Mingbo;WANG Zhilu(Department of Cardiology,The First Hospital of Lanzhou University,Lanzhou 730000,Gansu,China)
出处
《心血管病学进展》
CAS
2019年第1期92-95,共4页
Advances in Cardiovascular Diseases
关键词
心脏起搏器
除颤器
植入型
磁共振成像
Pacemaker
Defibrillators
Implantable
Magnetic resonance imaging