摘要 本文以节能减排以及保护环境为出发点,利用空气源热泵结合承压式热水贮水罐特有的热水加热系统以及送冷管道的间歇式送风功能,设计出空气源热泵与厨房新风系统的联供系统。经济效益方面,以某宾馆空气源热泵系统冷风收集利用改造项目为研究对象,实际生产运行结果表明:该系统年平均综合能效比实际综合能效比>4.2,真正实现了节能环保及降低运营成本的目的,从而验证了该系统的可行性与科学性。 In this paper,based on energy saving and environmental protection,the air source heat pump is combined with the special hot water heating system of the pressurized hot water storage tank and the intermittent air supply function of the cooling pipeline to design the air source heat pump and the kitchen.The joint system of the fresh air system.In terms of economic benefits,the cold air collection and utilization project of a hotel air source heat pump system is taken as the research object.The actual production operation results show that the annual average energy efficiency ratio of the system is more than 4.2,which truly achieves energy conservation and environmental protection and reduces operating costs.The purpose is to verify the feasibility and scientificity of the system.