摘要
引入十八胺停炉保养技术用于锅炉汽水系统,同时,结合300MW发电机组检修,创造性采用分系统小循环冲洗与汽水系统大循环冲洗相结合的方式,有效缩短了汽水品质恢复时长,为其他冶金企业设备防腐保养提供了新思路。
The octadecylamine furnace shutdown maintenance technology was introduced into the boiler steam water system.At the same time,combination of subsystem small cycle washing and steam water big cycle washing was creatively adopted in the 300MW generator maintenance,which effectively shortened the recovery period of steam water quality and provides a new approach to equipment anticorrosion and maintenance for other steelmakers.
作者
杨星辉
牛东风
YANG Xinghui;NIU Dongfeng(Shougang Jingtang United Iron and Steel Co.,Ltd.,Tangshan,Hebei 063210,China)
出处
《冶金动力》
2019年第3期39-41,45,共4页
Metallurgical Power
关键词
机组
腐蚀
汽水品质
保养
分系统冲洗
generator unit
corrosion
steam water quality
maintenance