摘要
利用定容燃烧弹试验装置,分别改变定容弹燃烧室内充气密度及喷油孔直径获得不同的湿壁条件,充气密度及喷孔直径范围分别为7.5~15.0kg/m^3及0.11~0.22mm,采用高速摄像机拍摄研究了不同湿壁条件对喷雾碰壁燃烧过程的影响。结果表明:喷雾燃烧滞燃期随充气密度的减小而增大,并且随着湿壁程度的增加而增加,滞燃期受充气密度的影响更显著。而在给定的高喷油压力高进气密度条件下,不同喷孔直径下的喷雾雾化效果都十分良好,喷雾着火主要受化学准备时间影响,滞燃期的波动不大。随着湿壁程度的加重,喷雾燃烧更晚进入高温着火阶段,后燃现象加重,燃烧持续期增长,碳烟的生成量急剧增多。
By using the wet conditions generated by changing the air change density(7.5 kg/m 3 to 15.0 kg/m 3)and injection hole diameter(0.11 mm to 0.22 mm)in a constant volume combustion chamber test device,a high-speed camera was used to study the effect of different wet wall conditions on the spray wall impingement combustion process.The ignition delay of spray combustion increases with the decrease of the air charge density and increases with the rise of wall humidity,but it is more significantly affected by the air charge density.For the given high fuel injection pressure and air intake density,spray atomization with different injection hole diameters is very good.The spray ignition is mainly influenced by the time of chemical preparation,and the fluctuation of ignition delay is not large.With the increase of humidity on the wall,the time for the spray burning to outer the high temperature ignition phase will be much later.Resulting in a serious post-combustion and increased combustion duration,which leads to a sharp increase in soot emissions.
作者
蓝天凯
黄荣华
黄胜
杨震寰
李志鹏
王龙飞
LAN Tiankai;HUANG Ronghua;HUANG Sheng;YANG Zhenhuan;LI Zhipeng;WANG Longfei(China-EU Institute for Clean and Renewable Energy,Huazhong University of Science&Technology,Wuhan 430074,China;China North Engine Research Institute,Tianjin 300400,China)
出处
《内燃机工程》
EI
CAS
CSCD
北大核心
2019年第1期15-20,共6页
Chinese Internal Combustion Engine Engineering
基金
国防重大基础研究项目~~
关键词
定容弹
湿壁条件
喷雾碰壁燃烧
碳烟
constant volume combustion chamber
wet-wall condition
spray wall impingement combustion
soot