摘要
二等水准测量属于精密水准测量,其精度要求高,在施测过程中,应对误差进行严格控制。文章结合使用数字水准仪进行二等水准测量的测算实例,逐层分析了误差来源,并提出相应的误差控制措施。
Second-class leveling is a kind of precision leveling,which requires high precision.The error should be strictly controlled in the process of measurement.In connection with the calculation of the second level measurement by using a digital level gauge,the source of error was analyzed by layer and the corresponding error control measures were put forward.
作者
王海帆
WANG Hai-Fan(Hunan Communication Engineering Polytechnic,Changsha,Hunan 410000,China)
出处
《企业技术开发》
2018年第12期59-61,共3页
Technological Development of Enterprise
关键词
工程测量
二等水准测量
误差
Engineering survey
Second-Class Leveling
Error