摘要 本文通过对原子荧光仪器条件、磷酸用量、硼氢化钾及氢氧化钠浓度等试验条件进行优化,采用原子荧光光谱仪测定锗的含量。结果表明,该法的检出限为0.1μg/g,测定的8个国家标准物质与推荐值相符,且重复测定12次的相对误差≤2%。 In this paper,the experimental conditions of atomic fluorescence instrument,phosphoric acid dosage,potassium borohydride and sodium hydroxide concentration were optimized,and the content of germanium was determined by hydride generation-atomic fluorescence spectrometry after alkali fusion.The results showed that the detection limit of the method was 0.1μg/g,and the value of eight national standard substances determined were in agreement with the recommended value,and the relative error value repeatedly measured 12 times was≤2%.
作者 马凤英 胡兰 赵玲 MA Feng-ying;HU Lan;ZHAO Ling(Anhui Institute of Geological Experiment,Hefei Anhui 230001)
出处 《现代农业科技》 2019年第2期134-135,共2页 Modern Agricultural Science and Technology
关键词 土壤 氢化物原子荧光光谱法 碱熔 soil germanium generation-atomic fluorenscence spectrometry alkali fusion