摘要
分析了国华神华绥中发电有限公司1号和2号超临界锅炉顶棚水冷壁泄漏的主要原因,结合锅炉实际情况,提出了相应的改造方案,为锅炉顶棚水冷壁的改造提供依据。
This paper analyzes the main causes of the roof water-cooling wall leakage in No.1 and No.2 supercritical boilers in Guohua Shenhua Suizhong Power Generation Co.,Ltd.,Combining the actual operating conditions of the boilers,it puts forward a reform project which provides a foundation for the reform of the roof water-cooling wall.
作者
国成江
李长宽
冷杰
张力杰
蒙毅
GUO Chengjiang;LI Changkuan;LENG Jie;ZHANG Lijie;MENG Yi(Guohua Shenhua Suizhong Power Generation Co.,Ltd.,Huludao,Liaoning 125222,China;Liaoning North Branch of China Huaxi Engineering Design & Construction Co.,Ltd.,Shenyang,Liaoning 110003,China;Electric Power Research Institute of State Grid Liaoning Electric Power Co.,Ltd.,Shenyang,Liaoning 110006,China;Xi'an Thermal Power Research Institute Co.,Ltd.,Xi'an,Shanxi 710054,China)
出处
《东北电力技术》
2018年第11期54-57,共4页
Northeast Electric Power Technology
关键词
超临界锅炉
顶棚水冷壁
泄漏
治理
supercritical boiler
roof water-cooling wall
leakage
governance