摘要 文章介绍了某火力发电厂600MW发电机由于转子动叶片断裂造成的振动增大现象的分析与处理过程。通过对发电机转子动叶片材质、制造工艺和安装过程的深入分析,研究发电机转子动叶片断裂的主要原因,制定预防措施,成功治理了设备隐患。 This paper introduces the analysis and treatment process of vibration-increased of 600MW generator that caused by rotor moving blade fracture in a thermal power plant.Through the in-depth analysis of the material,manufacturing process and installation process of the rotor moving blade of the generator,the main reasons for the fracture of the rotor moving blade of the generator are studied,and the preventive measures are formulated.The hidden trouble of the equipment is successfully treated.
作者 赵明远 ZHAO Mingyuan(Shenhua Shaanxi Guohua Jinjie Energy Limited Liability Company,Shenmu,Shaanxi,719319)
出处 《神华科技》 2018年第12期58-60,共3页 Shenhua Science and Technology
关键词 600MW发电机 动叶片 断裂 分析与处理 600MW generator Moving blade Fracture Analysis and treatment