期刊文献+

蒸发冷却制冷机组与冷凝模块炉酒店应用初探

Combined Application of Evaporative Cooling Chiller and Condensing Gas Furnace Module in Hotel
下载PDF
导出
摘要 本文通过经济性分析,探讨酒店空调及生活热水的冷、热源采用蒸发冷却式制冷机组与冷凝燃气模块炉方案的合理性。结合工程案例,对蒸发冷却式制冷机组+冷凝燃气模块炉、水冷式制冷机组+燃气锅炉、风冷式制冷机组+燃气锅炉三种方案的经济性进行了对比,结果表明:酒店空调及生活热水的冷、热源采用蒸发冷却式制冷机组+冷凝模燃气块炉更加合适。 By economic analysis, rationality of the scheme for adopting evaporative cooling chiller and condensing gas modular as the cold & heat sources for air conditioners and domestic hot water in hotels was studied. The economic analysis of three schemes: evaporative cooling chiller & condensing gas furnace module, water-cooled chiller & gas boiler, air-cooled chiller & gas boiler was conducted, and the result shows that the evaporative cooling chiller & condensing gas furnace module scheme is more appropriate for air conditioners and domestic hot water in hotels.
作者 向操 XIANG Cao(Guangzhou Municipal Engineering Design & Research Institute)
出处 《建筑热能通风空调》 2019年第1期83-85,93,共4页 Building Energy & Environment
关键词 蒸发冷却式制冷机组 冷凝燃气模块炉 经济性分析 evaporative cooling chiller condensing gas furnace module economic analysis
  • 相关文献

参考文献2

二级参考文献7

  • 1中国建筑标准设计研究院.全国民用建筑工程设计技术措施节能专篇暖通空调·动力[M].北京:中国计划出版社,2007
  • 2电子工业部第十设计院.空气调节设计手册[M].2版.北京:中国建筑工业出版社,1995:212.
  • 3上海市城乡建设和交通委员会.GB50015-2003建筑给水排水设计规范(2009年版)[s].北京:中国计划出版社,2010:92-95,100.
  • 4陆耀庆.实用供热空调设计手册(第二版)[M].北京:中国建筑工业出版社,2009.
  • 5中国建筑科学研究院.民用建筑供暖通风与空气调节设计规范《31350736-2012)[S].北京:中国建筑工业出版社,2012.
  • 6中国建筑标准设计研究院,建设部工程质量安全监督与行业发展司.全国民用建筑工程设计技术措施节能专篇.暖通空调动力-2007[M].北京:中国计划出版社,2007.
  • 7陈耀辉.全热回收风冷热泵机组在酒店中的应用[J].给水排水,2008,34(7):77-80. 被引量:6