锥形束CT引导乳腺癌精确放疗的研究进展 被引量:10

Research progress on cone-beam CT image-guided precise radiotherapy of breast cancer
下载PDF
导出
摘要 机载锥形束CT(CBCT)作为重要的图像引导装置,广泛应用于乳腺癌放射治疗摆位误差的测量。众多文献研究显示通过CBCT扫描,乳腺癌放射治疗靶区各个方向上的摆位误差控制在5 mm以内。对比电子射野影像仪,CBCT扫描有着巨大的临床优势,特别是对于大乳房患者,但是CBCT的使用所带来的额外辐射剂量可能会增加第二原发肿瘤的发生,需要更多的临床研究来评估CBCT扫描在乳腺癌放射治疗中的作用。 On-board cone-beam CT(CBCT)has been widely used in imaged-guided radiotherapy of breast cancer for measuring the setup errors.So far,numerous studies have revealed that the average setup error in CBCT image-guided radiotherapy of breast cancer is controlled within 5 mm.Compared with electronic portal image devices,CBCT has tremendous advantages,especially for large-breasted patients.However,the use of CBCT significantly increases the dose to organs-at-risk,which potentially increases the likelihood of developing a secondary malignancy.Further studies are needed to assess the benefits of CBCT in breast radiotherapy.
作者 陈绍芳 CHEN Shaofang(Department of Radiation Oncology,Zhejiang Cancer Hospital,Hangzhou 310022,China)
出处 《中国医学物理学杂志》 CSCD 2019年第2期163-165,共3页 Chinese Journal of Medical Physics
基金 浙江省医药卫生科技项目(2017PY013)
关键词 锥形束CT 乳腺癌 精确放疗 综述 cone-beam computed tomography breast cancer precise radiotherapy review
  • 相关文献

参考文献4

二级参考文献34

  • 1于金明,袁双虎.图像引导放射治疗研究及其发展[J].中华肿瘤杂志,2006,28(2):81-83. 被引量:99
  • 2Brabbins D, Martinez A, Yah D, et al. A dose-escalation trial with the adaptive radiotherapy process as a delivery system in localized prostate cancer: analysis of chronic toxicity [ J ]. Int J Radiat Oncol Biol Phys, 2005, 61 (2) :400-408.
  • 3Uehzhsffer S, Zygmanski P, Hesser J, et al. Clinical application of varian OBI CBCT system and dose reduction techniques in breast cancer patients setup [ J ]. Med Phys, 2010, 37 (6) : 2985- 2998. DOI: 10.1118/1.3432617.
  • 4O'Connell A, Conover DL, Zhang Y, et al. Cone-beam CT for breast imaging: radiation dose, breast coverage, and image quality [J]. AJR Am J Roentgenol, 2010, 195(2):496-509. DOI 10. 2214/A JR.08.1017.
  • 5Han C, Schiffner DC, Schultheiss TE, et al. Residual setup errors and dose variations with less-than-daily image guided patient setup in external beam radiotherapy for esophageal cancer[ J]. Radiother Oncol, 2012, 102(2) : 309-314.
  • 6van Herk M, Remeijer P, Rasch C, et al. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy [ J ]. Int J Radiat Oncol Biol Phys, 2000, 47(4) : 1121-1135.
  • 7van Herk M. Errors and margins in radiotherapy[ J]. Semin Radiat Oncol, 2004, 14(1) :52-64.
  • 8Glide-Hurst CK, Shah MM, Price RG, et al. Intrafraction variability and deformation quantification in the breast[ J]. Int J Radiat Oncol Biol Phys, 2015, 91(3) :604-611. DOI: lO. 1016/j.ijrobp.2014. 11.003.
  • 9Donovan EM, Castellano I, Eagle S, et al. Clinical implemeolation of kilovoltage cone beam cr for the verification of sequential and integrated photon boost treatments for breast cancer patients [ J ]. Br J Radiol, 2012, 85 (1019) : e1051-e1057. DOI: 10. 1259/bjr/ 28845176.
  • 10Topolnjak R, Sonke JJ, Nijkamp J, et ah Breast patient setup error assessment : comparison of electronic portal image devices and cone- beam computed tomography matching results [ J ]. Int J Radiat Oncol Biol Phys, 2010, 78(4) :1235-43. DOI: lO. lO16/j.ijrobp. 2009.12.021.

共引文献50

同被引文献86

引证文献10

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部