期刊文献+

交叉结构超声仿组织模体声速测量方法 被引量:2

Cross Structured Measurement Method of Sound Velocity of Ultrasound Tissue Mimicking Phantom
下载PDF
导出
摘要 针对超声仿组织模体内部材料的声速测量问题,提出一种十字交叉结构的双探头发射接收声速测量方法。首先将超声脉冲发射接收仪的高压脉冲信号一分为二,同时驱动2个交叉分布的超声换能器,并在接收端通过2个接收换能器接收透射时间差;然后测得模体的长短边距离,计算得到材料的声速;最后通过搭建测量系统与验证实验。结果表明,该方法可提高声速测量的准确性与实用性。 Aiming at the problem of measuring the sound velocity of the material inside the Tissue-mimicking phantom,a new method of measuring the sound velocity of the material by two-probe emission and reception with cross structure is proposed.By dividing the high-voltage pulse signal of the ultrasonic pulse emitter into two parts,and drive two cross-distributed ultrasonic transducers at the same time.The transmission time is received through two receiving transducers at the receiving end.The sound velocity of the material is calculated by measuring the long and short side distance of the module.The measurement system and validation experiments show that the method can improve the accuracy and practicability of sound velocity measurement.
作者 吴国光 李奇 陈上文 Wu Guoguang;Li Qi;Chen Shangwen(Guangdong Provincial Key Laboratory of Modern Geometric and Mechanical Metrology Technology;Guangdong Provincial Institute of Metrology)
出处 《自动化与信息工程》 2018年第5期10-12,17,共4页 Automation & Information Engineering
基金 广东省质量技术监督局科技计划项目(2018ZJ01)
关键词 交叉结构 仿组织模体 声速 Cross Structure Tissue Mimicking Phantom Sound Velocity
  • 相关文献

参考文献3

二级参考文献18

  • 1陆宣明,应崇福,周静华.生物组织超声散射的一种改进模型[J].声学学报,1989,14(5):346-356. 被引量:10
  • 2冯诺.超声手册[M].南京:南京大学出版社,1999.357.
  • 3GB15261-94超声仿人体组织材料声学特性的测量方法
  • 4D W RICKEY,P A PICOT, D A CHRISTOPHER,A FENSTER. A wall - less vessel phantom for Doppler ultrasound studies [ J ]. Elsevier Science, 1995,21 ( 9 ) : 1163 - 1176
  • 5IEC 61685 -2001 Ultrasonics Flow Measurement Systems Flow Test Object
  • 6S L Bridal, V Roberjot, P Laugier, G Berger. Attenuation and Backscatter Coefficient Measurements from 2 to 60 MHz [ J ]. IEEE ULTRASONICS SYMPOSIUM, 1996 : 1151 - 1154
  • 7Keith A Wear. Interlaboratory Comparison of Ultrasonic Backscatter Coefficient from 2 - 9 MHz [ J ]. American Institute of Ultrasound in Medicine, 2005, 24 : 1235 - 1250
  • 8Chen X, Phillips D, Schwarz KQ, Mottley JG, Parker KJ. The measurement of hackscatter coefficient from a broadband pulse - echo system: a new formulation[J]. IEEE Trans Ultrasonic Ferroelectric Freq Control 1997, 44:515 - 525
  • 9Rubens A Sigelmann, John M Reid. Analysis and measurement of ultrasound backscattering from an ensemble of scatters excited by sine - wave bursts [ J ] . Department of Electrical Engineering, 1973,53(5) : 1351 -1355
  • 10他得安,王威琪,汪源源,余建国.超声背散射系数在松质骨评价中的应用[OL].[2007-07-01],中国科技论文在线