期刊文献+

双源CT双能量成像在痛风尿酸盐结晶检测中应用价值 被引量:19

Application Value of Dual-source DualEnergy CT in the Detection of Gout Crystal
下载PDF
导出
摘要 目的探讨双源CT双能量成像在痛风尿酸盐结晶检测中应用价值。方法回顾性分析30例经临床确诊痛风患者和12例高尿酸血症患者的双能量CT表现。结果共30例痛风患者DECT发现尿酸盐结晶沉积,其中单关节受累17例,多关节受累13例,以指(趾)间关节及其周围软组织最明显;12例高血尿酸患者,DECT检查发现4例有尿酸盐结晶沉积。结论双源CT双能量成像技术具有简便、无创、快捷、灵敏、准确及可重复性强等优势,可以作为痛风诊断、疗效评估及痛风高危人群筛查的首选检查方法。 Objective To investigate the application value of dual source dual energy CT in the detection of gout crystals.Methods The dual energy CT findings of 30 patients with gout and 12 patients with hyperuricemia were analyzed retrospectively.Results Uric acid crystal deposition was detected in30 patients with gout,including 17 cases of single joint involvement and 13 cases of multiple joints involvement.The interphalangeal joint and its surrounding soft tissue were the most obvious.There were 4 cases were found uric acid deposit by DECT in 12 patients with hyperuricemia.Conclusion Dual-source dual-energy CT has the advantages of simple,non-invasive,rapid,sensitive,accurate and repeatable.It can be used as the preferred method for diagnosis,evaluation of therapeutic effect and screening of high-risk gout population.
作者 刘勇玲 范红燕 赵庆 慕建成 LIU Yong-ling;FAN Hong-yan;ZHAO Qing(CT Room,NO.2 Hospital of Jiaozuo,Jiaozuo 454000,Henan Province,China)
出处 《中国CT和MRI杂志》 2019年第2期143-145,共3页 Chinese Journal of CT and MRI
关键词 双源CT 双能量成像 痛风 尿酸盐结晶 Dual-source Dudl-energy Computed Tomography Gout Urate Crystal
  • 相关文献

参考文献7

二级参考文献50

  • 1麦垚.老年痛风性关节炎42例分析[J].中国误诊学杂志,2005,5(17):3350-3351. 被引量:5
  • 2张波,钱晓惠,田为中,窦小峰.双源CT双能量成像在痛风患者尿酸盐沉积诊断中的价值[J].中华临床医师杂志(电子版),2012,6(21):6993-6994. 被引量:3
  • 3李长勤,付建斌,孙庆举,谢元忠.痛风性关节炎的影像学诊断[J].泰山医学院学报,2006,27(5):384-386. 被引量:11
  • 4Desai MA, Peterson J J, Garner HW, et al. Clinical utility of dual - energy CT for evaluation of tophaceous gout [ J ]. Radio- graphics, 2011,31 ( 5 ) : 1365-1375.
  • 5Nicolaou S, Yong - Hing C J, Galea - Soler S, et al. Dual - en- ergy CT as a potential new diagnostic tool in the management of gout in the acute setting [ J ]. American Journal of Roentgenolo- gy, 2010,194(4) :1072-1078.
  • 6Glazebrook KN, Guimares LS, Murthy NS, et al. Identi cation of Intraarticular and Periarticular Uric Acid Crystals with Dual - Energy CT : Initial Evaluation [ J ]. Radiology, 2011,261 ( 2 ) : 516-524.
  • 7Choi HK, A1 - Arfaj AM, Eftekhari A, et al. Dual energy com- puted tomography in tophaceous gout [ J ]. Ann Rheum Dis, 2009,68 ( 10 ) : 1609-1612.
  • 8Grainger R, Taylor WJ, Dalbeth N, et al. Progress in measurement instrument s for acute and chronic gout studies IJ. J Rheumatol, 2009, 36(10): 2346-55.
  • 9Gruber M, Bodner G, Rath E, et al. Dual-energy computed tomography compared with ultrasound in the diagnosis of gout[J]. Rheumatology (Oxford), 2014, 53(1): 173-9.
  • 10Nicolaou S, Yong-Hing CJ, Galea-Soler S, et al. Dual-Energy CT as a potential new diagnostic Tool in the management of gout in the acute setting[J]. American Journal of Roentgenology, 2010, 194(4): 1072-8.

共引文献190

同被引文献168

引证文献19

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部