摘要
[目的]为了探讨高烈度地区的结构动力弹性时程响应机理,文章采用某燃机发电厂集控楼进行弹性动力时程分析。[方法]根据目前的选波原则筛选出3条地震波,对该结构进行弹性动力时程分析。[结果]分析得出该结构在弹性动力时程分析中的结构响应结果,并与CQC振型分解反应谱法的结构响应进行对比。[结论]根据分析结果进一步探讨了该类结构在高烈度地区下的动力响应机理,对弹性动力时程分析结果的合理性和适用性进行论述,为该类结构的结构设计与分析提供参考与借鉴。
[Introduction]In order to investigate the mechanism of dynamic elastic time response of structures in high intensity regions,an elastic dynamic time-history analysis is carried out for a central control building of a gas turbine generator plant.[Method]In this paper,three seismic waves were selected according to the current wave selection principle,and the elastodynamic time history analysis of the structure was carried out.[Result]The structural response result in the elastic dynamic time-history analysis is shown,which is compared with the structural response of the CQC mode decomposition response spectrum method.[Conclusion]Furthermore,according to the analysis result,the mechanism of structural dynamic response under high intensity region is investigated,the rationality and applicability of the elastic dynamic time history analysis are discussed,which provides reference for structural design and analysis of this kind of structure.
作者
陈康华
CHEN Kanghua(China Energy Engineering Group Guangdong Electric Power Design Institute Co.,Ltd.,Guangzhou 510663,China)
出处
《南方能源建设》
2018年第A01期140-145,共6页
Southern Energy Construction
基金
中国能建广东院科技项目"粘滞阻尼消能结构在地震高烈度区主厂房设计中的应用"(EX02011W)
关键词
高烈度地区
集控楼
弹性动力时程分析
结构响应
high intensity area
central control building
elastic dynamic time-history analysis
structural response