期刊文献+

煤中氯含量测量不确定度评定 被引量:3

Evaluation of uncertainty in measurement of chlorine in coal
下载PDF
导出
摘要 基于对煤中氯含量测量产生的误差与不确定度进行评定具有重要的意义,针对GB/T3558—2014 《煤中氯的测定方法》中高温燃烧水解—电位滴定法测煤中氯含量结果进行相应的不确定度评定。按照A、B类不确定度来分析与量化,重点对氯含量重复性测量、质量称量、硝酸银标准溶液的浓度及用量、电位测量、氯化钠标准溶液加入量的不确定度进行阐述,提出高温燃烧水解等不确定度对总量不确定度的合成影响不大,经过分析、量化、合成不确定度求得煤中氯含量的扩展不确定度为0.002 2%。 Based on that the evaluation of errors and uncertainties in measurement of chlorine in coal has significant difference,and regarding to results of chlorine determination using high temperature combustion hydrolysis-potentiometric titration method in GB/T 3558-2014 Determination of chlorine in coal,the uncertainty evaluation was done.According to the A,B type uncertainties,the analysis and measurement were done,and aspects such as chlorine content repeatability measurement,weight weighing,concentration and dosage of silver nitrate standard solution,potential measurement and uncertainty of sodium chloride standard solution addition amount were demonstrated,it was proposed that the uncertainty of high temperature combustion hydrolysis did not has big influence on the synthesis of total amount uncertainty,through analysis,quantification and synthesis of uncertainty,it was obtained that the extended uncertainty of chlorine in coal was为0.002 2%.
作者 苏龙 邓月明 莫晓山 胡彪 杨艳 SU Long;DENG Yue-ming;MO Xiao-shan;HU Biao;YANG Yan(College of Information Science and Engineering,Hunan Normal University,Changsha 410081,China;Hunan Institute of Metrology and Measurement,Changsha 410014,China)
出处 《煤质技术》 2019年第1期22-25,共4页 Coal Quality Technology
基金 物联网技术与应用重点实验室项目资助(HNU-2014-02)
关键词 煤中氯 不确定度 电位滴定 硝酸银标准溶液浓度 氯化钠标准溶液 chlorine in coal uncertainty potentiometric titration concentration of silver nitrate standard solution sodium chloride standard solution
  • 相关文献

参考文献5

二级参考文献23

共引文献41

同被引文献30

引证文献3

二级引证文献6