摘要 在低周反复荷载试验的基础上,对套筒灌浆连接的预制装配式剪力墙进行有限元分析,模拟分析轴压比、配筋率和配箍率等因素对剪力墙承载力和变形能力的影响。用ABACUS建立剪力墙非线性有限元模型,对比分析结果与试验结果,验证了有限模型的合理性。有限元模型可模拟实际预制剪力墙的受力性能,轴压比、配筋率、配箍率、混凝土强度对套筒灌浆连接的预制装配式剪力墙的承载力和变形能力影响较大,套筒位置、套筒数量对其影响较小,对这些参数进行合理的调整可以提高预制剪力墙的抗震性能。 Based on the experiments of the reversed low cyclic loads,the pre-cast shear walls with vertical reinforcements spliced by grout sleeves are studied by nonlinear finite element analysis,and the effects of ratios of axial compression,reinforcement ratios and stirrup ratios on loading capacity and deformability of the shear wall are further investigated.The nonlinear finite element model are established by ABACUS.Verifying the rationality of the model through comparing the results of the finite element analyses and the results of experiments,and the finite element model can simulate the actual behavior of the pre-cast shear walls.The factors such as the ratios of axial compression,the reinforcement ratios and stirrup ratios of side columns and the concrete grades have a great effect on the loading capacity and deformability of the pre-cast shear walls,and the location of grout sleeve,the number of grout sleeve has a little effect on it.The appropriate adjustments of these parameters can increase the seismic performance of the shear walls.
作者 葛华 黄浩 李付春 GE Hua;HUANG Hao;LI Fuchun(Sichuan Electric Power Design and Consulting Co.,Ltd.,Chengdu 610041,China;CMCU Engineering Co.,Ltd.,Chongqing 400039,China;State Power Grid Qingdao Power Supply Company,Qingdao 266022,China)
出处 《混凝土》 CAS 北大核心 2019年第1期86-89,共4页 Concrete
关键词 预制剪力墙 套筒灌浆连接 抗震性能 非线性有限元 pre-cast shear wall grout sleeve splicing seismic behavior nonlinear finite element analysis
  • 相关文献

参考文献3

二级参考文献42

  • 1严薇,曹永红,李国荣.装配式结构体系的发展与建筑工业化[J].重庆建筑大学学报,2004,26(5):131-136. 被引量:172
  • 2尹之潜,朱玉莲,杨淑文,李树桢,刘岩.高层装配式大板结构模拟地震试验[J].土木工程学报,1996,29(3):57-64. 被引量:18
  • 3GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 4JG儿01-96建筑抗震试验方法规程[s].北京:中国建筑工业出版社,1996.
  • 5.GB50010-2002混凝土结构设计规范[S].北京:中国建筑工业出版社,2002..
  • 6Ned M. Cleland. Design for lateral force resistance with precast concrete shear walls [ J ]. PCI Journal, 1997 (5) : 44 -64.
  • 7Pekau 0 A, Zielinski Z A, Lee A W K, et al. Dynamic effects of panel failure in preeast concrete shear walls [ J ]. ACI Structural Journal, 1988,85 (3) : 277 - 285.
  • 8Moehizuki S. Experiment on slip strength of horizontal joint of precast concrete multi story shear walls [ Jl. Eleven world conference on earthquake engineering, 1996,194 : 1 - 8.
  • 9Pekau O A. Influence of vertical joints on the earthquake response of precast panel walls [ J ]. Building and Environment, 1981 , 16 (2) :153 - 162.
  • 10Harry G. Harris, George Jau -jyh Wang. Static and dynamic testing of model precast concrete shearwalls of large panel buildings [ J ]. Special Publication, 1982,3 : 205 - 237.