摘要 分析了350MW超临界机组高中压转子振动问题的共性影响因素,按照与运行工况的相关度将高中压转子振动问题进行分类诊断,并给出相应治理措施;推算了高中压转子动平衡首次配重质量和滞后角取值范围。给出了油挡积碳碰摩和汽流激振故障治理方法,并介绍了临界转速区与工作转速区振动超标问题的动平衡处理案例,为类似故障的处理提供了参考。 The common influencing factors on HP/IP rotor vibration of 350MW supercritical unit were analyzed. According to the correlation with working conditions, the vibration problem was classified and diagnosed, and the corresponding measures were given. The ranges of the first counterweight and lag angle were quoted. Governance cases of rubbing of oil blocking and steam-excited vibration were introduced. It also mainly introduced the dynamic balance handling cases of excessive vibration in the critical speed region and the working speed region, which provided a reference for similar treatment.
作者 李晓波 俎海东 焦晓峰 LI Xiaobo;ZU Haidong;JIAO Xiaofeng(Inner Mongolia Power Research Institute, Hohhot 010020, China)
出处 《内蒙古电力技术》 2019年第1期16-20,共5页 Inner Mongolia Electric Power
基金 内蒙古电力科学研究院2016年自筹科技计划项目(510241160010K)
关键词 350MW超临界机组 振动 高中压转子 动不平衡 配重估算 滞后角 积碳 汽流激振 350MW supercritical steam turbine vibration HP/IP rotor dynamic imbalance weight estimation lag angle carbon deposition steam flow excited vibration