期刊文献+

氯离子检测技术探究——直接电位法 被引量:6

Exploration in Detection Technology of Chloride Ion—— Direct Potentiometry
下载PDF
导出
摘要 直接电位法是一种利用电极来检测水溶性氯离子含量的电化学方法,具有速度快、适用性广等优点,既可用于试验室检测,又可用于现场检测。文中的试验设计了四种浓度的NaCl标准溶液;并以此绘制了三种E-lg C关系曲线;对四种已知浓度的试验溶液分别采用三种E-lg C关系曲线进行推算;并对推算结果进行了对比分析。研究结果显示,选用与待测溶液浓度相适应的标准曲线进行推算,将极大地提高氯离子含量检测结果的准确性。 Direct potential test is an electron-chemical method of detecting water soluble chloride ion content with electrodes,fast in speed and wide in applicability,and can be applied both for test in laboratory and on site.We draw three kind of E-lg C relation curves upon NaCl standard solutions with four different concentrations designed in the experiment,calculate four solutions with known concentrations based on the three E-lg C relation curves,and compare and analyze the calculation results.The research results show that the test result accuracy for chloride ion content would be greatly improved when selecting standard curve which suits the concentration of solution to be measured.
作者 陈成 崔建生 龚燕华 倪磊 CHEN Cheng;CUI Jian-sheng;GONG Yan-hua;NI Lei(Nantong Academy of Architectural Sciences Co,Ltd,Nantong,226000,China)
出处 《建材世界》 2019年第1期102-105,116,共5页 The World of Building Materials
基金 江苏省住房和城乡建设厅科技计划(2017-ZD-165513104663)
关键词 氯离子选择电极 直接电位法 水溶性氯离子 标准溶液 chloride ion selective electrode direct potentiometry water soluble chloride ion standard solution
  • 相关文献

参考文献5

二级参考文献30

  • 1邱会东,雷新超,昝陆军,罗国兵.影响离子选择电极法测定污水中氟化物的几种因素[J].表面技术,2005,34(5):87-88. 被引量:5
  • 2包乃文,杨树才.地铁工程中高性能混凝土抗杂散电流腐蚀模拟试验研究[J].建筑科学,2006,22(4):47-50. 被引量:3
  • 3UHLIG H H, REVIE R W. Corrosion and Corrosion Con- trol[M]. 3rd ed. Hoboken New Jersey: John Weley Sons, 1985: 261-268.
  • 4山田佑定,高桑信?杉村登.迷走電流による鉄筋コンクリート中の鉄筋腐食について[J].ヤ技年披,昭和56,35(1):345-348.
  • 5STERN M, GEARY AL. Electrochemical Polarization: I. A Theoretical Analysis of the Shape of Polarization Curves[J]. Journal of Electrochemical Society, 1957, 104(11): 56-63.
  • 6中华人民共和国建设部,国家质量监督检验检疫总局.GB50344-2004建筑结构检测技术标准[S].北京:中国建筑工业出版社,2004.
  • 7ANDRADE C, ALONSO C. Corrosion Rate Monitoring in the Laboratory and on-site[J]. Construction Building Materials, 1996, 10(5)..315-328.
  • 8吴泉水.杂散电流与氯离子耦合作用下混凝土中钢筋锈蚀研究[D].南昌:华东交通大学,2011:43-45.
  • 9BERTOLINI L, LAZZARI L, PED P. Factors Influen- cing Stray Current Induced Corrosion in Reinforced Con- crete Structures [J]. Industrial Italiana Del Cemeto, 1996, 709(5) :268-279.
  • 10BERTOLINI L, CARSANA M, PEDEFERRI P. Corro- sion Behavior of Steel in Concrete in the Presence of Stray Current[J]. Corrosion Science, 2007, 49(3) : 1056-1068.