期刊文献+

PVA纤维束分散设备搅拌槽流场运动分析

Flow Field Motion Analysis on Stirred Tank of PVA Fiber Bundle Dispersing Equipment
下载PDF
导出
摘要 为了提高PVA纤维束分散设备的分散质量,研究PVA纤维束分散设备搅拌槽的分散能力,建立了分散设备的搅拌槽模型,以分散设备搅拌槽内安装挡板为研究对象,开展流场运动分析,探究搅拌槽内安装挡板对PVA纤维分散质量的影响,并进行了有、无挡板的对比试验,结果表明:在PVA纤维分散设备搅拌槽内添加挡板,可以有效改善搅拌槽内纤维速度和湍流动能,增加切向流,提高PVA纤维束分散质量。 In order to improve the dispersing quality of PVA fiber bundle dispersing equipment,the dispersing ability of stirring tank of PVA fiber bundle dispersing equipment was studied,and the stirring tank model of dispersing equipment was also established.Taking the baffle installed in agitation tank of dispersing equipment as the research object,the flow field motion analysis was carried out to explore the influence of baffle installation in stirred tank on the dispersion quality of PVA fibers.Furthermore,the comparative tests with and without baffle were carried out.The results show that installing the baffle in stirred tank of PVA fiber bundle dispersing equipment can effectively improve the fiber speed and turbulent kinetic energy in stirred tank,increase the tangential flow and improve the dispersion quality of PVA fiber bundles.
作者 曹源文 吴春洋 林艳文 夏柱林 郑南翔 CAO Yuanwen;WU Chunyang;LIN Yanwen;XIA Zhulin;ZHENG Nanxiang(School of Electromechanical and Automotive Engineering,Chongqing Jiaotong University,Chongqing 400074,P.R.China;Ji nan Qimen Expressway (Dangshan Section) Project Office,Suzhou 235300,Anhui,P.R.China;School of Highway Engineering,Chang an University,Xi an 710064,Shaanxi,P.R.China)
出处 《重庆交通大学学报(自然科学版)》 CAS CSCD 北大核心 2019年第3期129-134,共6页 Journal of Chongqing Jiaotong University(Natural Science)
基金 安徽省交通科技基金项目(Ahjtki20140051) 河南省交通厅项目(Hnxrc2013001)
关键词 机械工程 PVA纤维束 搅拌槽 流场运动分析 mechanical engineering PVA fiber bundle stirred tank flow field motion analysis
  • 相关文献

参考文献1

二级参考文献8

  • 1Fukuyama H, Sato Y, Li V C, et al. Ductile En- gineered cementitious composites elements for seis- mic structural application [A]. In: Proceedings of the 12 WCEE[C] : 2000.
  • 2Takashima H, Miyagai K, Hashida T. Fracture Properties of discontinuous fiber reinforced cementi- tous composites manufactured by extrusion molding [A]. In: Proceedings of the JCI International work- shop on ductile fiber reinforced cementitious com- posites (DFRCC) - Application and Evaluation (DRFCC-2002) [C]. Takayama, Japan, Oct. 2002: 75-84.
  • 3Zhang J, Li V C. Effect fiber rupture load in fiber of inclination angle on reinforced cementitiouscomposites [J]. Composites Science and Technology, 2002, 62: 775-781.
  • 4Maalej M, Li V C, Hashida T. Effect of fiber Rupture on tensile properties of short fiber compos- ites[J]. ASCE J. Engineering mechanics, 1995, 121 (8): 903-913.
  • 5Kanda T, Li V C. Interface property and appar- ent strength of High - Strength hydrophilic fiber in cement matrix [J]. J. of materials in civil engineering, ASCE, 1998, 10(1): 5-13.
  • 6Redon C, Li V C, Wu C, et al. measuring and modifying interface properties of PVA fiber in ECC Matrix [J]. Journal of materials in civil engineering, 2001, (12):399-406.
  • 7Li V C, Wu C, Wang S X, et al. Interface tai- loring for strain hardening polyvinyl alcohol- engi- neered cementitious composite (PVA-ECC) [J]. ACI materials journal,2002, 99(5): 462-471.
  • 8钱桂枫,高祥彪,钱春香.PVA纤维对混凝土力学性能的影响[J].混凝土与水泥制品,2010(3):52-54. 被引量:53

共引文献6