期刊文献+

DGT600-250给水泵推力瓦温高的原因分析及处理措施

Cause Analysis and Treatment Measures for High Temperature of Feed Pump Thrust
下载PDF
导出
摘要 上海电力修造总厂生产的DGT600-250汽动给水泵返厂检修后,装复试运过程中出现推力瓦温持续升高,机组负荷超过160 MW时推力瓦温度超过报警1值,并且随着负荷升高推力瓦温仍持续升高,通过分析润滑油压、油温、流量、油路等方面的问题,查找出推力瓦温高的原因,提出有效处理措施解决了推力瓦温高的现场难题。 After the DGT600-250 steam feed pump produced by Shanghai Electric Power Repair and Repair Plant was returned to the factory for repair, the thrust tile temperature continued to rise during the trial and test. When the unit load exceeded 160 MW, the thrust tile temperature exceeded the alarm 1 value, and As the load increases, the thrust tile temperature continues to rise. By analyzing the problems of lubricating oil pressure, oil temperature, flow rate, oil path, etc., the cause of thrust tile temperature high is found out, and effective treatment measures are proposed to solve the thrust tile temperature is high on-site puzzles.
作者 徐勇忠 李勤 XU Yongzhong;LI Qin(Jiangxi Electric Power Engineering Co.,Ltd. Guixi Branch,Guixi 335400,Jiangxi,China;SPIC Jiangxi Electric Engineering Co.,Ltd. Fenyi Power Plant,Xinyu 336607,Jiangxi,China)
出处 《能源研究与管理》 2019年第1期78-81,共4页 Energy Research and Management
关键词 推力瓦 润滑油 回油挡板 节流孔板 thrust tile lubricating oil oil return baffle throttle plate