摘要
通过分析LNG的相关参数及其危险性,指出了加气站的消防安全设计中存在的问题及安全威胁,并提出改进建议,希望能提升相关加气站建设的消防水平,减少人员伤亡及损失。
In this paper,the related parameters of LNG and its risk are analyzed. The existing problems and security threats in fire safety design of gas station are pointed out. Suggestions for improvement are put forward. It is hoped that the fire fighting level of relevant gas stations will be raised. Reduce casualties and losses.
作者
匡文杰
Kuang Wenjie(Feixian Public Security Fire Brigade,Linyi 273400,China)
出处
《山西建筑》
2019年第8期239-240,共2页
Shanxi Architecture
关键词
液化天然气
加气站
消防安全
liquified natural gas
filling station
fire safety