期刊文献+

车用不同光束角灯具的光通量测试技术探讨

Study on Luminous Flux Measurement Technology of Different Beam Angle Lighting Fixtures for Automobiles
下载PDF
导出
摘要 为研究不同光束角的灯具光通量测试技术,用光束角分别为10°~120°的12只灯具样品进行实验。将灯具安装在积分球的几何中心,设置光束轴线与光度探测器平面的垂线的夹角,测试不同安装角度情况下灯具的光通量,结果表明积分球测量光束角小于100°的灯具存在较大偏差。使用分布光度计在不同的测试角度间隔下进行实验,只要选择合适的测试角度间隔就可得到精确可靠的结果。 To study the luminous flux test technology of different beam angle,the lamps have been studied,in which beam angles rang from 10°to 120°.Lamps are installed in the geometric center of integrating sphere.The lu-minous flux is tested with setting the angle between beam axis and the vertical of photometric detector plane.The results show that the lamp with a beam angle of less than 100°will produce a large deviation.Goniophotometer is used to test luminous flux at different angular intervals.The results show that,appropriate angular intervals selection can produce accurate and reliable results.
作者 李海涛 王永春 康乐 LI Hai-tao;WANG Yong-chun;KANG Le(CCIC WEST Testing Company Limited,Xi’an 710032,China)
出处 《汽车电器》 2019年第3期64-66,共3页 Auto Electric Parts
关键词 光通量 积分球 分布光度计 光束方向 光束角 luminous flux tntegrating sphere goniophotometer light direction beam angle
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部