摘要
作为发电机核心部件,定子线棒的健康程度对于发电机至关重要,若定子线棒出现不同程度的电晕腐蚀缺陷,将对发电机的安全稳定运行产生严重后果。针对深溪沟水电站发电机运行维护检修过程中出现的实际情况,对出现电晕腐蚀的线棒进行统计,分析其主要部位产生电晕腐蚀的原因,并研究探索出了切合实际的处理方法,使问题得到有效的解决。
As the core component,the stator bar is of great importance to the generator.If corona corrosion defect occurs in the stator bar,the safe and stable operation of the generator could be seriously affected.Based on the practical maintenance experience of Shenxigou Hydropower Station,the corona corrosion faults observed in stator bars are summarized.Possible reasons of the corona corrosion in major parts are analyzed and feasible treatment measures are proposed considering the actual conditions.Practice shows that the problem is solved effectively.
作者
袁林
徐青彪
熊荣
胡方圆
YUAN Lin;XU Qingbiao;XIONG Rong;HU Fangyuan(Dadu River Hydropower Development Co.,Ltd.,China Energy Investment Corporation,Leshan 614900,China)
出处
《水电与新能源》
2019年第3期61-64,共4页
Hydropower and New Energy
关键词
发电机
线棒
电晕
腐蚀
高阻
高阻漆
generator
winding bar
corona
corrosion
high resistance
high resistance paint