为研究山西古交矿区地层电性参数,提高瞬变电磁探测异常区的解释精度,以古交矿区屯兰煤矿瞬变电磁探测结果为研究对象,采用探采对比和统计学原理进行研究分析。研究结果表明该研究区低阻异常区的门槛值为5Ω·m,高阻异常区的门槛值为200Ω·m,高于200Ω·m应解释为陷落柱,当达到260Ω·m时应解释为断层。
In order to study the electrical parameters of strata in Gujiao mining area, Shanxi Province, and improve the interpretation accuracy of the abnormal areas of transient electromagnetic detection, this paper takes the transient electromagnetic detection results of Tunlan Coal Mine in Gujiao mining area as the research object, and uses the contrast of exploration and mining and the principle of statistics for research and analysis. The research results show that the threshold low resistivity anomaly area in the study area is 5Ω?m, abnormal high resistance in the threshold value is 200Ω?m, more than 200Ω?m should be interpreted as collapse column, when 260Ω?m should be interpreted as fault.
作者
郭盛彬
Guo Sheng-bin(Xishan Coal Power Group Co., Ltd., Shanxi Taiyuan 030053)
出处
《山东煤炭科技》
2019年第3期169-171,共3页
Shandong Coal Science and Technology
关键词
古交矿区
瞬变电磁探测
异常区门槛值
Gujiao mining area
transient electromagnetic detection
threshold value of abnormal region