磷酸浓缩系统石墨换热器离线清洗实践

Practice of Offline Cleaning of Graphite Heat Exchanger in Phosphoric Acid Concentration System
下载PDF
导出
摘要 阐述磷酸浓缩石墨换热器在生产过程中因结垢堵塞,造成生产装置产能下降。介绍了石墨换热器除垢的方法及原理,并结合生产实践,总结了有效的石墨换热器离线清洗清理方法,采用酸洗、碱洗相结合的三次清垢法,以提高磷酸浓缩系统的生产负荷。 The reduced capacity of the plant due to plugging caused by fouling in the operation of the graphite heat exchanger in the phosphoric acid concentration is described. The method and principle for the foul removal of the graphite heat exchanger are outlined. Based on the actual operation practice, the effective online cleaning method for the graphite heat exchanger is summarized. A three-time foul cleaning method combining acid cleaning and alkaline cleaning is employed to increase the operating load of the phosphoric acid concentration system.
作者 胡友强 HU You-qiang(Guiyang Kailin Fertilizer Co., Ltd., Guiyang 551109, China)
出处 《硫磷设计与粉体工程》 2018年第5期39-41,I0002,共4页 Sulphur Phosphorus & Bulk Materials Handling Related Engineering
关键词 磷酸浓缩 石墨换热器 结垢 离线清洗 效果 phosphoric acid concentration graphite heat exchanger fouling offline cleaning effect