摘要
串联补偿技术是解决配网10kV线路电压质量问题的有效手段,但补偿点及补偿容量的确定尚无实用的程序化方法。研究在潮流计算的基础上,针对农网典型的10kV线路末端低电压、末端T接小水电线路电压波动问题,提出基于综合能效分析的固定串联补偿位置及容量的程序化确定方法。
Series compensation technology is an effective means to solve the voltage quality problem of 10 kV line in distribution network,but there is no practical programmed method to determine the compensation point and compensation capacity.On the basis of power flow calculation,a programmed method for determining the fixed series compensation position and capacity based on comprehensive energy efficiency analysis is proposed to solve the voltage fluctuation problems of typical 10 kV line terminal low voltage and small hydropower line terminal T connection.
作者
于浩
齐国刚
叶青
董钟泽
Yu Hao;Qi Guo-gang;Ye Qing;Dong Zhong-ze
出处
《电力系统装备》
2019年第4期18-19,共2页
Electric Power System Equipment