期刊文献+

可降解下腔静脉滤器的生物力学性能及有限元分析 被引量:5

Biomechanical Properties and Finite Element Analysis of the Biodegradable Inferior Vena Cava Filter
下载PDF
导出
摘要 利用有限元分析和径向支撑力测试,分析不同支撑杆数目对新型生物可降解下腔静脉滤器(inferior vena cava filters, IVCF)的生物力学性能的影响。应用三维建模软件建立支撑杆数目为8, 10, 12的IVCF模型;通过室温拉伸左旋聚乳酸得到其应力-应变曲线,使用Abaqus软件模拟分析3种支架在压握和自扩张过程中的生物力学性能;同时将3种IVCF进行径向支撑力测试。结果表明,3种支架的应力峰值不同,但应力分布趋势相同;其径向支撑力随支撑杆数目的增加而减小,自扩张性能则与之相反;10杆IVCF表现出较好的综合力学性能,经压握后不仅有足够的径向支撑力,而且可以实现自我扩张,对血管壁的损伤最小。 The effects of support pole numbers on biomechanical properties of a novel biodegradable inferior vena cava filter(IVCF) were investigated by finite element analysis and radial force tests. The IVCF model with 8, 10 and 12 supporting poles were established by three-dimensional modeling software. The stress-strain curve of poly L-lactide fibers was obtained by tensile test at room temperature. The biomechanical properties of the three stents under crimp and expansion condition were then simulated and analyzed by using the Abaqus software. Meanwhile, the three IVCFs were subjected to radial support force test. The results show that the three stents shows different peak stresses with similar trend of stress distribution. The radial support force decreases with the increase in the supporting pole numbers. However, the self-expansion performance shows the opposite trends. The 10 pole IVCF performs the superior comprehensive mechanical property, which includes sufficient radial force after crimp, achievement of self-expansion, and the least damage to vessel wall.
作者 杨彩红 马凤仓 姜洪焱 高晨光 刘祥坤 黄男男 YANG Caihong;MA Fengcang;JIANG Hongyan;GAO Chenguang;LIU Xiangkun;HUANG Nannan(School of Materials Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;Shanghai MicroPort Medical (Group) Co., Ltd., Shanghai 201203, China)
出处 《有色金属材料与工程》 CAS 2019年第1期20-26,共7页 Nonferrous Metal Materials and Engineering
基金 先进金属电力材料重点实验室(17ZR1419600) 上海市科学技术委员会(11441900501)
关键词 可降解下腔静脉滤器 生物力学性能 有限元分析 biodegradable inferior vena cava filter biomechanical property finite element analysis
  • 相关文献

参考文献5

二级参考文献89

  • 1柳清菊,张瑾,朱忠其,张海滨,吴兴惠.载银TiO_2无机抗菌剂的制备及性能研究[J].功能材料,2005,36(3):474-476. 被引量:13
  • 2高振宇,梁栋科,齐民,杨大智,王伟强.镍钛合金超弹性支架抗压缩性能的实验与分析[J].功能材料与器件学报,2006,12(1):49-53. 被引量:6
  • 3翟仁友,戴定可,于建.下腔静脉滤器的临床应用[J].中华外科杂志,1996,34(8):512-512. 被引量:3
  • 4Schtinemann HJ, Jaeschke R, Cook DJ, et al. An official ATS statement: grading the quality of evidence and strength of recommendations in ATS guidelines and recommendations. Am J Respir Crit Care Med,2006,174(5):605-614.
  • 5Geerts WH, Pineo GF, Heit JA, et al. Prevention of venous thromboembolism: the Seventh ACCP Conference on antithrombotic and thrombolytie therapy. Chest, 2004, 126 (3 Suppl) : 338S-400.
  • 6Cook D,Crowther M,Meade M,et al. Deep venous thrombosis in medical-surgical critically ill patients : prevalence ,incidence, and risk factors. Crit Care Med,2005,33(7):1565-1571.
  • 7Ibrahim EH, Iregui M,Prentice D, et al. Deep vein thrombosis during prolonged mechanical ventilation despite prophylaxis. Crit Care Med,2002,30(4) :771-774.
  • 8Shorr AF,Williams MD. Venous thromboembolism in critically ill patients, observations from a randomized trial in sepsis. Thromb Haemost, 2009,101 (1): 139-144.
  • 9Muscedere JG, Heyland DK, Cook D. Venous thromboembolism in critical illness in a community intensive care unit. J Crit Care,2007,22(4) :285 289.
  • 10Hirsch DR, Ingenito EP, Goldhaber SZ. Prevalence of deep venous thrombosis among patients in medical intensive care. JAMA,1995,274(4) :335-337.

共引文献55

同被引文献51

引证文献5

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部