期刊文献+

Optimization of the gas separation performance of polyurethane–zeolite 3A and ZSM-5 mixed matrix membranes using response surface methodology

Optimization of the gas separation performance of polyurethane–zeolite 3A and ZSM-5 mixed matrix membranes using response surface methodology
下载PDF
导出
摘要 In the present work, the response surface method software was used with five measurement levels with three factors.These were applied for the optimization of operating parameters that affected gas separation performance of polyurethane–zeolite 3A, ZSM-5 mixed matrix membranes.The basis of the experiments was a rotatable central composite design(CCD).The three independent variables studied were: zeolite content(0–24 wt%), operating temperature(25–45 ℃) and operating pressure(0.2–0.1 MPa).The effects of these three variables on the selectivity and permeability membranes were studied by the analysis of variance(ANOVA).Optimal conditions for the enhancement of gas separation performances of polyurethane–3A zeolite were found to be 18 wt%, 30 ℃ and 0.8 MPa respectively.Under these conditions, the permeabilities of carbon dioxide, methane, oxygen and nitrogen gases were measured at 138.4, 22.9, 15.7 and 6.4 Barrer respectively while the CO_2/CH_4, CO_2/N_2 and O_2/N_2 selectivities were 5.8, 22.5 and 2.5, respectively.Also, the optimal conditions for improvement of the gas separation performance of polyurethane–ZSM 5 were found to be 15.64 wt%, 30 ℃ and 4 bar.The permeabilities of these four gases(i.e.carbon dioxide, methane, oxygen and nitrogen) were 164.7, 21.2, 21.5 and 8.1 Barrer while the CO_2/CH_4, CO_2/N_2 and O_2/N_2 selectivities were 7.8, 20.6 and 2.7 respectively. In the present work, the response surface method software was used with five measurement levels with three factors.These were applied for the optimization of operating parameters that affected gas separation performance of polyurethane–zeolite 3A, ZSM-5 mixed matrix membranes.The basis of the experiments was a rotatable central composite design(CCD).The three independent variables studied were: zeolite content(0–24 wt%), operating temperature(25–45 ℃) and operating pressure(0.2–0.1 MPa).The effects of these three variables on the selectivity and permeability membranes were studied by the analysis of variance(ANOVA).Optimal conditions for the enhancement of gas separation performances of polyurethane–3A zeolite were found to be 18 wt%, 30 ℃ and 0.8 MPa respectively.Under these conditions, the permeabilities of carbon dioxide, methane, oxygen and nitrogen gases were measured at 138.4, 22.9, 15.7 and 6.4 Barrer respectively while the CO_2/CH_4, CO_2/N_2 and O_2/N_2 selectivities were 5.8, 22.5 and 2.5, respectively.Also, the optimal conditions for improvement of the gas separation performance of polyurethane–ZSM 5 were found to be 15.64 wt%, 30 ℃ and 4 bar.The permeabilities of these four gases(i.e.carbon dioxide, methane, oxygen and nitrogen) were 164.7, 21.2, 21.5 and 8.1 Barrer while the CO_2/CH_4, CO_2/N_2 and O_2/N_2 selectivities were 7.8, 20.6 and 2.7 respectively.
出处 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期110-129,共20页 中国化学工程学报(英文版)
关键词 Response surface method (RSM) MIXED matrix membranes Analysis of variance (ANOVA) OPTIMUM conditions Response surface method(RSM) Mixed matrix membranes Analysis of variance(ANOVA) Optimum conditions
  • 相关文献

参考文献1

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部